C
CM35
Specify the DP Make Ratio.
Assign the DTMF signal width to the trunk
route.
NOTE:
To reduce the connecting time, it is
recommended to shorten the DTMF
inter-digital Pause timing (Y=24),
i.e., second data=2 (80 ms.). Y=26,
i.e., second data=0 (64 ms.).
Assign the trunk release by detection of rever-
sal of tip and ring to the trunk route.
CAUTION:
Specify the DP Sender release timing to the
trunk route.
D
DESCRIPTION
Check the timing on main PBX before making any change on timing function.
CHAPTER 3 SYSTEM DATA PROGRAMMING
TRUNK DATA PROGRAMMING (For Adjunct Analog)
Y=25
(1)
00-63: Trunk Route No.
(2)
0 : 39 % Make Ratio
1 : 33 % Make Ratio
Y=26
(1)
00-63: Trunk Route No.
(2)
0 : 64 ms.
1 : 128 ms.
Y=39
(1)
00-63: Trunk Route No.
(2)
0 : Not released
1 : To release
Y=45
(1)
00-63: Trunk Route No.
(2)
0 : 2 seconds
1 : 4 seconds
2 : 6 seconds
3 : 8 seconds
4 : 12 seconds
5 : 14 seconds
6 : 16 seconds
7 : 10 seconds
– 126 –