Table of Contents

Advertisement

D
CMAD
Assign the data for wireless synchronization
between IP-CSs, if required.
NOTE:
Data setting of CMAD Y=32-39 is
not required for a normal operation.
You do not have to change the data
from initial setting.
E
DESCRIPTION
CHAPTER 3 SYSTEM DATA PROGRAMMING
Y=32 (Timing until Submaster IP-CS starts
(1)
000-255: CS No.
(2)
01-14: 6-84 seconds
(6 second increments)
15
: 30 seconds
Y=33 (Time limit for initial synchronous
(1)
000-255: CS No.
(2)
01-14: 1.5-21 seconds
(1.5 second increments)
15
: 15 seconds
Y=34 (Time limit for receiving the notice
(1)
000-255: CS No.
(2)
01-14: 100-1400 ms.
(100 ms. increments)
15
: 500 ms.
Y=35 (Number of continuation synchro-
(1)
000-255: CS No.
(2)
01-14: 1-14 messages
15
: 4 messages
Y=36 (Time limit for receiving the LCCH
(1)
000-255: CS No.
(2)
01-14: 1.5-21 seconds
(1.5 second increments)
15
: 6 seconds
– 107 –
CS DATA PROGRAMMING
DATA
up)
processing)
message of wireless channel infor-
mation at the synchronous process-
ing)
nous bit off message for judging a
gap)
for judging a gap)