RRP10.5 PWBA DUPLEX (PL10.1)

Removal
1)
Remove the COVER LEFT (PL 10.1). (RRP10.9)
2)
Remove the COVER RIGHT (PL 10.1). (RRP10.10)
3)
Remove the COVER TOP (PL 10.1). (RRP10.4)
4)
Disconnect the harness connectors from the connectors (P/J50, P/J51, P/J52, P/J53 and P/J
54) on the PWBA DUPLEX.
5)
Remove the 2 screws (gold tapping, 8mm x 1, gold, 6mm x 1) securing the PWBA DUPLEX to
the COVER HSG DUP (PL 10.1).
6)
Remove the PWA DUPLEX.
Replacement
1)
Install the PWBA DUPLEX to the COVER DUPLEX (PL 10.1) using the 2 screws (gold tapping,
8mm x 1, gold, 6mm x 1).
Install the PWA DUPLEX to the COVER DUPLEX in the direction shown in the
figure.
Be sure to tighten the screw (gold, 6mm) shown as Screw (A) in the figure.
2)
Connect the harness connectors to the connectors (P/J50, P/J51, P/J52, P/J53 and P/J54) on
the PWBA DUPLEX.
3)
Install the COVER TOP (PL 10.1). (RRP10.4)
Chapter 3 Removal and Replacement Procedures (RRPs)
Screw(A)
PWBA DUPLEX
(PL21.1.32)
3 - 169
52
53 54
51
P/J50
COVER HSG DUP
(PL21.1.18)
J23605AA