FIP3.11 SOLENOID ASSY GATE

Step
Possible causes:
SOLENOID ASSY GATE (PL23.1.27) P
WBA OCT (PL23.1.22)
HARNESS ASSY OCT2 (PL23.1.25)
HVPS/MCU (PL12.1.19)
HARNESS ASSY OCT1 (PL12.1.26)
Checking SOLENOID ASSY GATE
Not using DIAG tool: Replace SOLENOID ASSY GATE.
(RRP23.9)
Is the problem cleared?
1
Using DIAG tool: Is the feed-switching operation of
SOLENOID ASSY GATE correctly?
Check using Chapter 2 Diagnostic [Option Direction
Test].
2
Is the problem cleared?
Checking SOLENOID ASSY GATE
3
Replace SOLENOID ASSY GATE. (RRP23.9)
Is the problem cleared?
Checking HARNESS ASSY OCT2 for continuity
Disconnect P/J70 on PWBA OCT.
4
Remove HARNESS ASSY OCT2.
Is there continuity between J70 and J3070?
Checking HARNESS ASSY OCT1 for continuity
5
Remove HARNESS ASSY OCT1.
Is there continuity between J30 and J3070?
Checking PWBA OCT
6
Replace PWBA OCT. (RRP23.7)
Is the problem cleared?
Check
1 – 92
Chapter 1 Troubleshooting
Yes
End of work
Go to step 4.
Go to step 2.
Go to step 3.
Go to FIP3.8
End of work
PWBA OCT.
End of work
Go to step 4.
Replace HAR-
Go to step 5.
NESS ASSY
Replace HAR-
Go to step 6.
NESS ASSY
Replace HVPS/
End of work
MCU. (RRP12.10)
No
OCT2.
OCT1.