Fip3.9 Motor Assy Oct - Oki B6500 Service Manual

Hide thumbs Also See for B6500:
Table of Contents

Advertisement

FIP3.9 MOTOR ASSY OCT

Step
Possible causes:
MOTOR ASSY OCT (PL23.1.6)
PWBA OCT (PL23.1.22)
HARNESS ASSY OCT MOT (PL23.1.46)
HARNESS ASSY OCT2 (PL23.1.25)
HVPS/MCU (PL12.1.19)
HARNESS ASSY OCT1 (PL12.1.26)
Checking HARNESS ASSY OCT MOT for continuity
1
Remove HARNESS ASSY OCT MOT.
Is there continuity between J71 and J710?
Checking MOTOR ASSY OCT
Using DIAG tool: Does the MOTOR ASSY OCT rotate?
2
(Check by the rotating sound of the motor.)
Check using Chapter 2 Diagnostic [OCT Motor Test].
Checking MOTOR ASSY OCT
Not using DIAG tool: Replace MOTOR ASSY OCT.
3
(RRP23.13) Is the problem cleared?
4
Is the problem cleared?
Checking HARNESS ASSY OCT2 for continuity
Disconnect P/J70 from PWBA OCT.
5
Remove HARNESS ASSY OCT2.
Is there continuity between J70 and J3070?
Checking HARNESS ASSY OCT1 for continuity
6
Remove HARNESS ASSY OCT1.
Is there continuity between J30 and J3070?
Checking PWBA OCT
7
Replace PWBA OCT. (RRP23.7)
Is the problem cleared?
Check
1 – 90
Chapter 1 Troubleshooting
Yes
With tool Go to
Replace HAR-
step 2. Without
NESS ASSY OCT
tool Go to step 3.
Go to step 4.
Go to step 3.
End of work
.Go to step 5.
Go to FIP3.8
End of work
PWBA OCT.
Replace HAR-
Go to step 6.
NESS ASSY
Replace HAR-
Go to step 7.
NESS ASSY
Replace HVPS/
End of work
MCU (RRP12.10)
No
MOT.
OCT2.
OCT1.

Advertisement

Table of Contents
loading