5-2 Basic Functions

5-2 Basic Functions

The following explains the basic parameters such as RUN Command Selection and
Acceleration/Deceleration Time.

Heavy Load/Light Load Selection

The rated specification of the Inverter is selected from the two types: heavy load rating and light
load rating.
The rated current is different between the heavy load rating and light load rating, and the
electronic thermal characteristics, overload warning level and other items also vary
accordingly. Select either type according to the load actually used.
When the setting of Heavy Load/Light Load Selection is changed, the parameters shown in the
table below are reset to their default values and at the same time the heavy load/light load
rating changes. There is no need to reconnect the power or perform initialization.
The high-frequency mode is supported only when the heavy load rating is selected. For the
high-frequency mode, refer to "Inverter Mode Selection" on page 5-175.
Parameter
5
b049
The features of the heavy load mode and light load mode are described below.
Feature
Application
Rated current (example) 1.0 A (3-phase 200 V 0.1 kW)
Overload current rating
The setting ranges and default values of the following parameters are different between the
heavy load rating and light load rating. Take note that when the heavy load/light load setting is
changed using b049, the default values of all these parameters other than H003/H203 will also
change. (Even when the parameters shown in the table below are set to values within a range
supported by both the heavy load mode and light load mode, these values will be reset to the
default value once b049 is changed.)
Parameter
A044/A244
5-13
Function name
No.
Heavy Load/Light
Load Selection
A load that requires high torque
under certain conditions such as at
the start and during acceleration/
deceleration.
Lifts, cranes, conveyors, etc.
150% 60 s
Function name
No.
Control Method
1/2
Data
00: Heavy load mode (CT)
01: Light load mode (VT)
Heavy load (CT)
Heavy load (CT)
Setting range
Default value
00: Constant
00: Constant
torque
torque
01: Reduced
torque
02: Free V/f
setting
03: Sensorless
vector control
SYSDRIVE MX2 Series USER'S MANUAL (3G3MX2-Axxxx)
Default
setting
00
Light load (VT)
A load that does not require much
torque.
Fans, pumps, air-conditioners, etc.
1.2 A (3-phase 200 V 0.1 kW)
120% 60 s
Light load (VT)
Setting range
Default value
00: Constant
00: Constant
torque
torque
01: Reduced
torque
02: Free V/f
setting
Unit