Omron SYSDRIVE MX2 SERIES User Manual page 364

Multi-function compact inverter
Hide thumbs Also See for SYSDRIVE MX2 SERIES:
Table of Contents

Advertisement

6-8 List of Modbus Communication (Modbus-RTU) Data
Register
No.
226Fh
2270h
2271h
2272h
2273h
2274h
2275h
2276h
2277h
2278h
to
6
230Bh
230Ch Electronic Thermal Level 2
230Dh
230Eh
to
2315h
2316h
2317h Overload Limit 2 Level
2318h
2319h
to
2428h
2429h Overload Warning Level 2
6-71
Parameter
Function name
2nd Acceleration Time 2
2nd Deceleration Time 2
2-step Acceleration/
Deceleration Selection 2
2-step Acceleration
Frequency 2
2-step Deceleration
Frequency 2
Not used
Electronic Thermal
Characteristics Selection 2
Reserved
Overload Limit 2
Selection
Overload Limit 2
Parameter
Not used
Monitor and setting
R/W
No.
parameters
A292
R/W
(HIGH)
1 to 360000
A292
R/W
(LOW)
A293
R/W
(HIGH)
1 to 360000
A293
R/W
(LOW)
00: Switched via 2CH
terminal
01: Switched by setting
A294
R/W
02: Enabled only when
switching forward/
reverse
A295
R/W
(HIGH)
0 to 40000 (100000)
A295
R/W
(LOW)
A296
R/W
(HIGH)
0 to 40000 (100000)
A296
R/W
(LOW)
Inaccessible
b212
R/W 2000 to 10000
00: Reduced torque
characteristics
b213
R/W
01: Constant torque
characteristics
02: Free setting
00: Disabled
01: Enabled in acceleration/
constant speed
operation
02: Enabled in constant
b221
R/W
speed operation
03: Enabled in acceleration/
constant speed
operation
(Accelerates during
regeneration)
b222
R/W 100 to 2000
b223
R/W 1 to 30000
Inaccessible
C241
R/W 0 to 2000
SYSDRIVE MX2 Series USER'S MANUAL (3G3MX2-Axxxx)
Data
Page
resolution
0.01 [s]
0.01 [s]
5-66
0.01 [Hz]
0.01 [Hz]
0.01 [%]
5-110
5-114
0.1 [%]
0.1 [s]
0.1 [%]
5-115

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents