8-1 Inspection and Maintenance
Inspection
part
Cooling
system
Fault
display
Motor
8
*1.Smoothing capacitor life depends on ambient temperature.
Refer to " Appendix-2 Smoothing Capacitor Life Curve" for the replacement reference.
*2.The life of the cooling fan varies depending on the environmental conditions, such as ambient
temperature and/or dust. Check the operation through daily inspections.
*3.The replacement reference (year/cycles) and diagram of smoothing capacitor life are based on the
expected design life, which is not guaranteed.
8-5
Inspection
Inspection point
item
Cooling
Check that there
fan
are no abnormal
vibrations or
sounds.
Check that the
connection parts
are secure.
Cooling
Check that there
Fin
is no clogging.
Fault
Check that the
display
LED indicators
are lit properly.
Cleaning
Meter
Check that the
indicated value is
normal.
General
Check that there
are no abnormal
vibrations or
sounds.
Check that there
are no abnormal
odors.
Insulation
Megger check
resistance
(Between the
collective motor
terminals and
ground terminal)
Inspection
period
Periodic
Inspection
method
Rotate manually
when the power is
off.
Visual inspection
Visual inspection
Visual inspection
Clean with a
waste cloth.
Check the indicated
values on the panel
meters.
Acoustic, feeling,
and/or visual
inspection
Check that there
is no abnormal
odor caused by
damage or
overheating.
Disconnect
Inverter main
circuit terminals
U/T1, V/T2, and
W/T3, and short-
circuit the motor
wires (3 phases).
Then, use a
megger to
measure the
resistance
between the
motor wires and
ground terminal.
SYSDRIVE MX2 Series USER'S MANUAL (3G3MX2-Axxxx)
Measurement
Criteria
device
Rotation shall be
smooth and free
from error.
Reference of the
replacement period:
*2 , *3
10 years
No clogging.
Check that the
LED indicators
are lit.
The specified or
Voltage,
control values
Ammeter,
must be satisfied.
etc.
No faults
No faults
5 MΩ min.
500 V
class DC
megger