Command/Reference Input From the Control Circuit Terminal Block
Operates the Inverter by connecting the external signals (frequency setting volume, switch,
etc.) to the control circuit terminal block.
<Setting the Forward/Reverse Direction Using the FW/RV Input Terminal and Setting
the Frequency Using the Frequency Volume>
Setting
Parameter
No.
Frequency
A001
Reference
Selection 1
RUN Command
A002
Selection 1
Multi-function
C001
Input 1 Selection
Multi-function
C002
Input 2 Selection
Change the following parameters, if necessary:
Parameter
No.
Acceleration
F002
Time Setting 1
Deceleration
F003
Time Setting 1
Wiring the Control Circuit Terminal Block
10 VDC
FS
Frequency setting
*1 Allocate 16: FV/FI (Analog input switch) to a multi-function input to use as the voltage setting. If terminal
FV/FI is not allocated, the frequency reference becomes the sum of voltage input (FV) and current input
(FI). To use only one of voltage or current, therefore, short the other analog input to the SC terminal.
*2 This wiring diagram shows an example of using the built-in power supply of the Inverter. If an external
power supply is used, refer to "Connection to Programmable Controller (PLC)" on page 2-22.
Operation
Refer to "Test Run" on page 3-10.
SYSDRIVE MX2 Series USER'S MANUAL (3G3MX2-Axxxx)
Function name
Data
01 (Control circuit
terminal block)
01 (Control circuit
terminal block)
00 (FW: Forward)
01 (RV: Reverse)
Function name
0.01 to 99.99 s 100.0 to 999.9 s
1,000. to 3,600. s
0.01 to 99.99 s 100.0 to 999.9 s
1,000. to 3,600. s
FV
FI
SC
*1
volume
Default
value
02
02
If other input terminal is used, the
00(FW)
parameter number becomes different.
If other input terminal is used, the
01(RV)
parameter number becomes different.
Default
Data
value
10.00 s
10.00 s
F/R
STP
STA
setting
setting
setting
S3/GS1
S2
S1
SC
Reverse
Forward
input
input
3-2 Operation Method
Note
24 VDC
PSC
P24
*2