Interactive Menu Mode Programming (

[✻] + interactive mode No.
Press
procedure (with displays of prompts) is provided in later sections of this manual.
✻ 56 Enhanced Zone Programming Mode
Interactive menu mode used for programming zone attributes and report codes. Refer to the ✻ 56
Enhanced Zone Programming Mode section for procedure.
✻ 80 Device Programming Menu Mode
Interactive menu mode for programming Powerline Carrier Devices. Refer to the ✻ 80 Device
Programming Menu Mode section for detailed procedure.
✻ 81 Zone Lists Menu Mode
Interactive menu mode for programming zone lists for Powerline Carrier Devices. Refer to the ✻ 81
Zone List Menu Mode section for detailed procedure.
✻ 83 Enhanced Sequential Mode
Interactive menu mode used to enter RF transmitter serial numbers. Refer to the ✻ 83 Enhanced
Sequential Mode section for detailed procedure.
✻ 84 Assign Zone Voice Descriptors
Interactive menu mode used to assign descriptors to each zone. These descriptors will be announced
whenever the system announces an event involving a zone.
✻ 85 Record Custom Voice Descriptors
Interactive menu mode used to record custom descriptors for use with each zone.
✻ 96 Initialize Download ID and Subscriber Account Number for Downloading
Entering ✻ 96 resets all subscriber account numbers and CSID in preparation for an initial download.

Loading Factory Defaults

If a default table is loaded, any data that has already been programmed into the system will be changed
according to the default table selected!
✻ 97 To load the factory defaults, enter ✻97, then press number 1, 2, 3, or 4 to select from default tables
or press "0" if you are not selecting a default table. Refer to the Programming Default Tables section of this
manual to view the tables.

Exiting Program Mode

Do not exit Program Mode via *98 if you intend to enter LRR Communication Device Diagnostic Mode.
✻98 Exits program mode and inhibits re-entry into the Expert or Voice Prompt Programming modes using
the Installer Code.
✻99 Exits program mode but
800 or into the Voice Prompt Programming mode using Installer Code (4112) + 888.
Note: After exiting program mode (or upon power-up), the system takes up to a minute to reset. To bypass the reset
delay, press [#] + [0].
56
, ✻
(i.e., ✻56). The keypad will display the first of a series of prompts. A detailed
allows re-entry into the Expert Program mode using Installer Code (4112) +
- 17 -