Factory Set Condition - Honeywell Accenta Series Engineer's Manual

Table of Contents

Advertisement

Accenta/Optima Engineer's Manual

Factory Set Condition

User code1
User code2
Duress Code
Engineer Code
External siren Bell Duration
External siren Bell Delay
Rearm Count
Program 1
Zone 1
Timed
Zone 2
Timed inhibit
Zone 3 - 8 Immediate
Exit time
30 seconds
Entry time 30 seconds
Exit mode Timed
Program 2
Zone 1
Timed
Zone 2
Timed inhibit
Zone 3 - 8 Immediate
Exit time
30 seconds
Entry time 30 seconds
Exit mode Disabled
Program 3
Zone 1
Timed
Zone 2
Timed inhibit
Zone 3 - 8 Immediate
Exit time
30 seconds
Entry time 30 seconds
Exit mode Disabled
Zones
Security zones
Standard Fire zones
Double Knock zones
0123
Not programmed
Not programmed
9999
15 minutes
No delay
3 Rearms
Zones 1 - 8
None programmed
None programmed
Factory Conditions
Omit prevent zones
Flag 1
Silent PA
RKP PA Enable
Engineer Reset
User reset PA
User Reset Fire
Bell in Fire
Enable Zone 7 as Fire
Enable Zone 8 as Fire
NOTE:
Zone debounce period is 400 ms
Flag 2
Single Key setting
Strobe on setting
Flag 3
Accenta Optima Version X.XX
NOTE: X.XX indicates panel version eg 1.00
Refer to page 17, Defaulting Panel to
Factory Settings for the method of
defaulting the panel.
13
All programmed
No
Yes
No
No
No
No
No
No
No
No