Lynx Plus Series Installation and Setup Guide
✻ 56 Enhanced Zone Programming Mode
F F F F
DELETE ZONE
DELETE
DELETE
DELETE
ZONE
ZONE
ZONE
IA IA IA IA
ENROLL MODE
ENROLL
ENROLL
ENROLL
MODE
MODE
MODE

Delete Zone Parameters Confirmation

This function deletes either the serial number or all zone information that is
programmed for the zone.
If "00" was entered in the zone type, the confirmation of the delete request will delete
all information associated with the zone currently being programmed.
If "0" was entered in the loop number, the confirmation of the delete request will delete
the serial number of the zone currently being programmed.
SELECTIONS
0 = discard the delete request
1 = confirm requested delete
Note: If 00 was entered as a zone type in prompt (b), 00 will be retained and system will
advance to prompt (1C).
Enroll Mode
This prompt can be used to confirm or enter a serial number. If "L" is displayed
following "1A", the serial number for this transmitter has already been entered. It may,
however, still be viewed, confirmed (only if in listen mode), or deleted. If "L" is not
displayed following "1A", the serial number for this transmitter has not been previously
entered. You may enter the serial number manually, copy the previous serial number,
return to Prompt (E) or enter the serial number later using the ✻83 Enhanced
Sequential Mode.
Confirm serial number - The serial number/loop number combination can be
confirmed after one transmission from a BR type device or two transmissions (fault and
restore) from a UR or RF type device. If a transmission is received that matches the
serial number and loop number entered, the system will confirm the reception by
announcing the Voice Descriptor for the zone, (if programmed), followed by three beeps,
and a "C" will appear on the display indicating the received serial number and loop
number have been confirmed. No further transmissions will be received.
Delete serial number - The serial number can be deleted by entering "9".
Manual entry - Enter "1" to advance to Serial number prompt (1b).
Copy the previous serial number - Enter "2" to copy the previous serial number
entered.
Return to Prompt (E) - Enter "#" to return to Loop Number prompt (E).
Enter transmitter later - Enter "0" or "✻" if you wish to enter the transmitter later,
using the ✻83 Enhanced Sequential Mode described later in this manual.
Notes: (1) Option 1 is not applicable if the serial number is already present.
(2) If Option 2 is entered and this is the 1st zone, no serial will be in the buffer and
the panel will emit a long beep. Not valid if serial number is already present.
(3) Options 3 and 9 are only valid if "L" is displayed. If "L" is not displayed, panel
will emit a long beep.
(4) The panel will listen only when it is in the idle loop waiting for key entry and a
serial number has been entered. If a key is entered, the function must be
completed and the panel will listen again.
(5) A long beep indicates illegal entry or duplicate serial number/loop entry.
SELECTIONS
0 = advance to the VOICE DESCRIPTOR prompt (1C) and save all zone parameters.
1 = enter now and proceed to SERIAL NUMBER prompt (1b).
2 = copy the last serial number entered into local ram.
9 = advance to F; delete existing serial number.
[✻] = advance to the VOICE DESCRIPTOR prompt (1C). This will save all zone parameters.
[#] = return to the LOOP NUMBER prompt (E).