Data Field Descriptions

The following pages list all data fields in this Control (in numerical order). Use the blank programming form
to record the data for this installation. Specific fields include options for programming that are unique to
the LynxSIA Plus version. Note that both keypad LEDs flash while in Programming mode. The LynxSIA
Plus version validates the data entry for the Fields listed below. If data entered is not within valid range,
the control will emit a long beep indicating that entry is rejected and will substitute the default value for the
invalid entry. The default value will be displayed on the keypad, and the control advance to the next field.
Field
Name
*34
Exit Delay
*35
Entry Delay 01
*36
Entry Delay 02
*50
Burglary Dial Delay
*57
False Alarm Options
*59
Exit Error Report Code
*64
Test Report Code
*68
Cancel Report Code
*69
Recent Closing Report Code
*76
Test Restore Report
*92
Swinger Shutdown
Note: Entering a number other than the one specified will give unpredictable results.
20 20 20 20
INSTALLER CODE
INSTALLER
INSTALLER
INSTALLER
CODE
CODE
CODE
21 21 21 21
QUICK
QUICK ARM
QUICK
QUICK
ARM ENABLE
ARM
ARM
ENABLE
ENABLE
ENABLE
22 22 22 22
K K K K EY EY EY EYP P P P A A A A D D D D B B B B ACKLI
ACKLIGHT
ACKLI
ACKLI
GHT
GHT
GHT
2 2 2 2 3 3 3 3
FORCED BYPASS
FORCED
BYPASS
FORCED
FORCED
BYPASS
BYPASS
24 24 24 24
RF RF RF RF HOUSE
HOUSE ID ID ID ID CODE
HOUSE
HOUSE
CODE
CODE
CODE
Default Value
60
30
30
2
7
1
10
10
1
10
1
Installer Code
The Installer Code is used to enter the 4-digit Master Security Code. See "Master Code"
in the System Operation section for procedure.
Note: LynxSIA Plus does not allow duplication of Installer code. If a duplicate code is
entered the entry is rejected and LYNX issues single long beep indicating rejection.
The old installer code remains unchanged.
SELECTIONS
Enter 4 digits (0-9)
Quick Arm Enable
If enabled, security code is not required to arm the system. The user simply presses and
holds down the AWAY or STAY key to arm.
SELECTIONS
0 = do not allow quick arm
1 = allow quick arm
Keypad Backlight Timeout
This option allows the choice of either always backlighting the keypad or turning the
backlighting off after 10 seconds of keypad inactivity.
SELECTIONS
0 = no timeout; always backlight keys
1 = turn backlighting off after inactivity
Forced Bypass
All zones bypassed by this function will be displayed after the bypass is initiated.
UL installations: must be 0 (no forced bypass)
SELECTIONS
0 = no forced bypass
1 = provide automatic bypass of all open (faulted) zones
RF House ID Code
The House ID identifies receivers and wireless keypads. If a 5804BD/5804BDV
Transmitter is to be used, a House ID Code MUST be entered, and the keypad should
be set to the same ID.
SELECTIONS
00 = disable all wireless keypad usage
01-31 = House ID
Valid Range
45-97
30-99
30-99
1-3
0-7
1-F
10-FF
10-FF
1-F
10-FF
1-2
- 20 -

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents