Interactive Mode Programming (∗ ∗ ∗ ∗ 56, *57, ∗ ∗ ∗ ∗ 58, ∗ ∗ ∗ ∗ 79, ∗ ∗ ∗ ∗ 80, ∗ ∗ ∗ ∗ 81, ∗ ∗ ∗ ∗ 82)
Entering Interactive Mode

Loading Factory Defaults/Initializing for Download

To Load Default Entries
To Initialize Download ID
Do not press
already programmed into the system will be changed!

Exiting the Programming Mode

Prevent installer code
reentry
Allow installer code
reentry

Zone Type Definitions

Zone types define the way in which the system responds to faults in each zone.
Zone Type
Description
Type 00
Program a zone with this zone type if the zone is not used.
Zone Not Used
• Assign to zones that are used for primary entry and exit.
Type 01
• Provides entry delay when zone is faulted if control is armed in the Away, Stay, or Night-Stay
Entry/Exit
Burglary #1
modes.
• No entry delay provided when the panel is armed in the Instant/Maximum mode.
• Entry delay #1 is programmable for each partition (field *35).
• Exit delay begins whenever the control is armed, regardless of the arming mode selected, and
is programmable (field ✱ 34).
• Assign to zones that are used for entry and exit and require more time than the primary
Type 02
Entry/Exit
entry/exit point.
Burglary #2
• Provides a secondary entry delay, in same manner as entry delay #1.
• Entry delay #2 is programmable for each partition (field *36).
• Exit delay is same as described for Type 01.
• Assign to all sensors or contacts on exterior doors and windows.
Type 03
• Provides an instant alarm if the zone is faulted when the panel is armed in the Away, Stay,
Perimeter
Burglary
Night-Stay, Instant or Maximum modes.
• Assign to a zone covering an area such as a foyer, lobby, or hallway through which one must
Type 04
Interior Follower
pass upon entry (to and from the keypad).
• Provides a delayed alarm (using the programmed entry 1 time) if the entry/exit zone is faulted
first. Otherwise this zone type gives an instant alarm.
• Active when the panel is armed in the Away mode.
• Bypassed automatically when the panel is armed in the Stay or Instant modes;
if armed in Night-Stay mode, zones assigned to zone list 05 (night-stay zone list) are not
bypassed when system armed in Night-Stay mode.
3-2
Press [ ∗ ] + [Interactive Mode No.] (for example, ∗ 56) while in Program Mode. The Alpha
display keypad will display the first of a series of prompts.
After making the appropriate entry, press the [∗] key to accept the entry and continue to
the next prompt.
Press ∗97 while in Program Mode. This resets all data fields to the default values shown
on the Program Form. Use ∗ 97 only if you wish to return to the original factory-
programmed defaults.
Press ∗96 while in Program Mode. This initializes the system for downloading and resets
all the subscriber account numbers and CSID.
97 to load defaults if any programming has been done previously—data
Press ∗98. Exits Programming Mode and prevents re-entry by:
Installer Code + [8] + [0] + [0]. To enter the programming mode if ∗ 98 was used to exit,
you must first power the system down. Then power up again, and press [∗] and [#] at the
same time, within 50 seconds of powering up.
See field *88 for other Program mode lockout options.
Press ∗99. Exits Programming Mode and allows re-entry by:
Installer Code + [ 8] + [0] + [0] or by: Pressing [∗] and [#] at the same time, within 50
seconds of power-up.