Sensor Reset

User Code Level: Master or Standard
Function: Resets smoke or glassbreak detectors. Also clears Fire
and Supervisory zone alarms and trouble keypad displays. Sensor
Reset also clears low battery displays if your system is using
wireless sensors.
Once smoke or glassbreak detectors have tripped, they must be
reset before they can detect any additional alarm conditions. When
Sensor Reset is selected, power to the detectors is temporarily
removed by the system allowing them to reset.
Make sure all smoke is cleared from around the area of the smoke
detectors before performing a Sensor Reset to prevent the alarm
from occurring again.
Resetting the Sensors
1.
Access the User Menu.
2.
When SENSOR RESET? is displayed, press any Select key.
The keypad displays SENSORS OFF for Þ ve seconds followed
by SENSORS ON.
3.
The keypad returns to the status display.
Enter your user code to reset sensors
While your system is disarmed, you can just enter your user code
and press COMMAND to reset the sensors. (This feature operates in
All/Perimeter and Home/Away systems only.)
This also activates the door strike if your system has an Easy Entry™
access control keypad.
16

Outputs On Off

User Code Level: Master or Standard.
Function: Allows you to turn the system's outputs on and off.
This function is used to individually turn your system's relay
outputs on and off. Your system may use these outputs to control
interior and exterior lighting, or heating, air conditioning, or other
appliances.
The names and numbers of the outputs on your system are located
in the System Setup section at the back of this guide.
Turning the Outputs On and Off
1.
Access the User Menu.
2.
Press the COMMAND key until OUTPUTS ON/OFF? displays.
3.
Press any one of the Select keys.
4.
The keypad displays OUTPUT: - ON OFF.
5.
Enter the output number you want to turn on or off. The
output number appears in the display.
6.
With the output number displayed, press the Select key
under ON or OFF. The output is then turned on or off,
depending on your selection, and remains in that state until
you change it.
7.
The system automatically removes the output number and a
new output number can be entered. Refer back to step 5.
To exit the Output menu option, press the Back Arrow key until you
have returned to the keypad's Status List.