Sign In
Upload
Manuals
Brands
Security Command Manuals
Keypad
XR500 Series
User Manuals: Security Command XR500 Series Keypad
Manuals and User Guides for Security Command XR500 Series Keypad. We have
3
Security Command XR500 Series Keypad manuals available for free PDF download: User Manual
Security Command XR500 Series User Manual (76 pages)
Executive Series Command Processor Panels
Brand:
Security Command
| Category:
Security System
| Size: 2 MB
Table of Contents
Silencing an Alarm
2
Table of Contents
3
Introduction
7
XR500 and XR100 Security Command™ Systems
7
About Your Security System
7
Parts of the System
7
LCD Keypad
7
Keypad User Menu
7
A Note about False Alarms
7
Test Your System Weekly
7
Emergency Evacuation Plans
8
Draw a Floor Plan of Your Home or Business
8
Develop Escape Routes
8
Decide Where to Meet
8
Practice Your Escape Plans
8
Early Detection
8
DMP Keypads
9
Security Command™, Thinline™, Aqualite™ Keypads
9
Clear Touch™ Keypads
10
Common Keys on All Keypads
10
Panic Functions
11
Security Command™, Thinline™, Aqualite™ Keypads
11
Using the Keypad
12
Multi-Lingual Display Option
12
Keypad Displays Current Programming
12
Multiple Displays (XR500 System Only)
12
Asterisks in Area Armed Displays
12
Keypad User Options
13
Backlighting Brightness
13
Internal Speaker Tone
13
Volume Level
13
Model Number
13
Keypad Address
13
Special Keypad Tones
13
What to Do When the Trouble Tone Sounds
14
DMP Wireless
14
Special Wireless Displays
15
Special Keypad Displays
15
Alarm
15
Trbl (Trouble)
15
Alarm Not Sent
15
Alarm Cancelled
15
Alarm Verified
15
Enter Code or Present Card
15
Try Again or Invalid Code/Card/Pin
16
Invalid Profile
16
Invalid Area
16
Invalid Time
16
Armed Area
16
Failed to Exit (Anti-Passback)
16
SYSTEM TROUBLE or SERVICE REQUIRED
16
System Busy
16
Test in Progress
16
Section
16
Understanding Security System Terms
16
Arming
17
Central Station Monitoring
17
Disarming
17
Fault
17
Zone
17
Instant Zone
17
24-Hour Zone
17
Entry or Exit Zone
17
Status
17
Armed Status
18
View Zone Status
18
Browser Feature
18
Arming and Disarming
19
General Arming Operation
19
Arming Functions
19
Key Fob Arming
20
Key Fob Disarming
21
Area System Arming Operation
21
Arming the Area System
21
Quick Arming
21
Checking the Armed Areas
22
Area System Disarming Operation
22
Disarming the Area System from the Keypad
23
Quick Disarming
23
All/Perimeter System Arming
23
System Ready/System Not Ready
23
All/Perimeter Shortcut Key Arming
23
Arming an All/Perimeter System
24
All/Perimeter System Disarming
24
Disarming an All/Perimeter System
25
Disarming During an Alarm
25
Home/Sleep/Away System Arming
25
System Ready/System Not Ready Keypad Displays
25
Home/Sleep/Away Shortcut Key Arming
25
Arming a Home/Sleep/Away System
26
Home/Sleep/Away System Disarming
26
Disarming a Home/Sleep/Away System
27
Disarming During an Alarm
27
Extending Schedules
27
Keypad Shortcut Keys
28
Arming Function
28
Sensor (Fire) Reset Function
28
Monitor (Chime) Function
28
User Menu
29
Accessing the User Menu
29
User Menu Options
29
Section
30
Alarm Silence
30
Using the Alarm Silence Function
30
Sensor Reset
30
Sensor (Fire) Reset Shortcut Key
30
Resetting the Sensors
30
Door Access
30
Using the Door Access
30
Armed Areas Display
31
Using the Armed Areas Function
31
Outputs on off
31
Turning the Outputs on and off
31
Browser Feature
31
Zone Status
32
Using the Zone Status Function
32
Browser Feature
32
Bypass Zones
32
Using the Bypass Zones Function
32
Browser Feature
33
Zone Monitor
33
Monitor (Chime) Shortcut Key
33
Testing Your System's Burglary Protection
33
Using the Zone Monitor Function
33
Browser Feature
34
System Status
34
Using the System Status Function
34
System Test
34
Using the System Test Function
34
Using the Panic Zone Test (XR500N/E Only)
35
User Profiles
35
Adding User Profiles
36
Browser Feature
36
Changing User Profiles
36
Browser Feature
37
Deleting User Profiles
37
Temp Code
37
Anti Pass no
37
Shift Time Access: 1 2 3 4 Anytime
37
Re Arm Delay
37
User Profiles Chart
38
User Codes
39
Adding User Codes
39
Browser Feature
40
Changing User Codes
40
Deleting User Codes
40
Browser Feature
41
Forgive Failure to Exit
41
Ambush Code
41
Schedules
42
Setting Shift (S1 S2 S3 S4) Schedules
43
Setting Output (OUT) and Door (DOOR) Schedules
44
Setting Holiday ABC Schedules for S1, S2, S3, S4, OUT, and DOOR Schedules
45
Setting Holiday Dates (HOL)
46
Extending Schedules (EXT)
46
Setting the Date and Time
47
Setting the System's Date and Time
47
Display Events
47
Service Request
48
Fire Drill
48
Starting a Fire Drill Test
48
Ending a Fire Drill Test
48
XR500/XR100 User's Guide
48
Section
49
System Setup
49
System Setup Record
49
Keypad Record
49
Key Fob Button Programming
50
Area Names and Numbers Record
51
User Profiles Record
52
User Codes Record
53
Schedules Record
54
Holiday Date Record
55
Output Relay Record
55
Appendix A
56
About the Display Events Section
56
Using the Display Events
56
Arming and Disarming Event Displays
57
Zone Event Displays
57
Supervisory Event Displays
57
User Code Change Event Displays
57
Zone Bypass Event Displays
57
Door Access Event Displays
58
About Door Access
58
System Monitor Event Displays
58
Schedule Change Event Displays
59
Wireless Jamming Event Displays
59
Wireless Trouble Event Displays
59
Appendix B
60
Zone Status Browser
60
Bypass Zones Browser
61
Zone Monitor Browser
61
Add User Codes Browser
62
Change User Codes Browser
62
Delete User Codes Browser
63
Add User Profiles Browser
63
Change User Profiles Browser
64
Delete User Profiles Browser
64
Output Groups Browser
65
Outputs On/Off Browser
65
Appendix C
66
User Disarm and Entry
66
Entering User Names
66
Appendix D
67
DMP Wireless Description
67
LED Status Operation
67
Appendix E
68
Easy Entry™ User's Guide
68
Door Strike
68
Arming and Disarming an Area System
68
Arming and Disarming an All/Perimeter System
69
Arming and Disarming a Home/Sleep/Away System
69
Disarming with Entry Delay
69
Frequently Asked Questions
70
Common Keypad Displays
71
Index
72
Advertisement
Security Command XR500 Series User Manual (68 pages)
Executive Series Command Processor Panels
Brand:
Security Command
| Category:
Security System
| Size: 1 MB
Table of Contents
Silencing an Alarm
2
Table of Contents
3
Introduction
7
About Your Security System
7
Parts of the System
7
LCD Keypad
7
Keypad User Menu
7
A Note about False Alarms
7
Test Your System Weekly
7
Emergency Evacuation Plans
8
Draw a Floor Plan of Your Home or Business
8
Develop Escape Routes
8
Decide Where to Meet
8
Practice Your Escape Plans
8
Early Detection
8
DMP Keypads
9
Security Command™, Thinline™, Aqualite™ Keypads
9
Clear Touch™ Keypads
10
Common Keys on All Keypads
10
Panic Functions
11
Security Command™, Thinline™, Aqualite™ Keypads
11
Using the Keypad
12
Multi-Lingual Display Option
12
Keypad Displays Current Programming
12
Multiple Displays
12
Asterisks in Area Armed Displays
12
User Options
13
Backlighting Brightness
13
Internal Speaker Tone
13
Volume Level
13
Model Number
13
Keypad Address
13
Special Security Command™ Tones
14
What to Do When the Trouble Tone Sounds
14
Special Security Command™ Displays
14
Alarm
14
Alarm Not Sent
14
Alarm Cancelled
14
Trouble
14
Enter Code
14
TRY AGAIN or INVALID CODE
15
Invalid Profile
15
Invalid Area
15
Invalid Time
15
Armed Area
15
Failed to Exit (Anti-Passback)
15
SYSTEM TROUBLE or SERVICE REQUIRED
15
System Busy
15
Test in Progress
15
Special Wireless Displays
15
Understanding Security System Terms
16
Access (Door Access)
16
Areas
16
Arming
16
Fault
16
Central Station Monitoring
16
Disarming
16
Entry or Exit Zone
16
Browser Feature
16
Status
17
Armed Status
17
View Zone Status
17
Zone
17
Instant Zone
17
24-Hour Zone
17
Arming and Disarming
18
System Arming Operation
18
Arming the System
19
Quick Arming
19
Checking the Armed Areas
19
System Disarming Operation
20
Disarming the System from the Keypad
21
Quick Disarming
21
Card Reader Disarming
21
Extending Schedules
21
User Menu
22
Accessing the User Menu
22
User Menu Options
22
Alarm Silence
23
Using the Alarm Silence Function
23
Sensor Reset
23
Resetting the Sensors
23
Door Access
24
Using the Door Access
24
Armed Areas Display
24
Using the Armed Areas Function
24
Outputs on off
25
Turning the Outputs on and off
25
Browser Feature
25
Zone Status
26
Using the Zone Status Function
26
Browser Feature
26
Bypass Zones
26
Using the Bypass Zones Function
26
Browser Feature
27
Zone Monitor
27
Testing Your System's Burglary Protection
27
Using the Zone Monitor Function
27
System Status
28
Using the System Status Function
28
System Test
28
Using the System Test Function
28
Using the Panic Zone Test
29
User Profiles
29
User Profiles Chart
30
Adding User Profiles
31
Browser Feature
31
Changing User Profiles
31
Deleting User Profiles
32
Browser Feature
32
Temp Code
32
Anti Pass no
32
Alow: 1 2 3 4 any
32
Re Arm Delay
32
User Codes
33
Adding User Codes
33
Browser Feature
33
Changing User Codes
34
Browser Feature
34
Deleting User Codes
34
Forgive Failure to Exit
35
Ambush Code
35
Schedules
36
Setting Shift (S1 S2 S3 S4) Schedules
37
Setting Output (OUT) and Door (DOOR) Schedules
38
Setting Holiday ABC Schedules for S1, S2, S3, S4, OUT, and DOOR Schedules
39
Setting Holiday Dates (HOL)
40
Extending Schedules (EXT)
40
Setting the Date and Time
41
Setting the System's Date and Time
41
Display Events
41
Service Request
42
Fire Drill
42
Starting a Fire Drill Test
42
Ending a Fire Drill Test
42
System Setup
43
System Setup Record
43
Keypad Record
43
Which Keypads Display System Status
44
Which Keypads Display Armed Status
44
Which Keypads Provide Door Access Reports
44
Area Names and Numbers Record
45
User Profiles Record
46
User Codes Record
47
Schedules Record
48
Holiday Date Record
49
Output Relay Record
49
Appendix A
50
About the Display Events Section
50
Using the Display Events
50
Arming and Disarming Event Displays
51
Zone Event Displays
51
Supervisory Event Displays
51
User Code Change Event Displays
52
Zone Bypass Event Displays
52
Door Access Event Displays
52
About Door Access
52
System Monitor Event Displays
53
Schedule Change Event Displays
53
Appendix B
54
Zone Status Browser
54
Bypass Zones Browser
55
Zone Monitor Browser
55
Add User Codes Browser
56
Change User Codes Browser
56
Delete User Codes Browser
57
Add User Profiles Browser
57
Change User Profiles Browser
58
Delete User Profiles Browser
58
Output Groups Browser
59
Outputs On/Off Browser
59
Appendix C
60
User Disarm and Entry
60
Entering User Names
60
Easy Entry™ User's Guide
61
Door Strike
61
Arming and Disarming an Area System
61
Disarming with Entry Delay
61
Using the Access Reader for User Menu Access
61
Frequently Asked Questions
62
Common Keypad Displays
63
Index
64
Security Command XR500 Series User Manual (62 pages)
Executive Series Command Processor Panels
Brand:
Security Command
| Category:
Keypad
| Size: 0 MB
Table of Contents
Table of Contents
3
Section Section
7
Introduction
7
About Your Security System
7
Parts of the System
7
Security Command Keypad
7
Keypad User Menu
7
A Note about False Alarms
7
Test Your System Weekly
7
Emergency Evacuation Plans
8
Draw a Ss Oor Plan of Your Home or Business
8
Develop Escape Routes
8
Decide Where to Meet
8
Practice Your Escape Plans
8
Early Detection
8
The Security Command Keypad
9
The Select Keys
9
Data Entry Keys
9
COMMAND Key
9
Back Arrow Key
9
Power Led
9
Armed Led
9
2-Button Panic Keys
9
Using the Keypad
10
Keypad Displays Current Programming
10
Multiple Displays Containing Programming
10
Asterisks in Programming
10
User Options
11
Backlighting Brightness
11
Internal Speaker Tone
11
Volume Level
11
Model Number
11
Keypad Address
11
Special Security Command Tones
11
What to Do When the Trouble Tone Is Sounding
11
Special Security Command Displays
12
Special Wireless Displays
13
Understanding Security System Terms
13
Status List
14
Arming and Disarming
15
System Arming Operation
15
Arming the System
16
Quick Arming
16
Checking the Armed Areas
16
System Disarming Operation
17
Disarming the System from the Keypad
18
Quick Disarming
18
Extending Schedules
18
User Menu
19
Accessing the User Menu
19
User Menu Options
19
Alarm Silence
20
Using the Alarm Silence Function
20
Sensor Reset
20
Resetting the Sensors
20
Door Access
21
Using the Door Access
21
Armed Areas Display
21
Using the Armed Areas Function
21
Outputs on off
22
Turning the Outputs on and off
22
Browser Feature
22
Zone Status
23
Using the Zone Status Function
23
Browser Feature
23
Bypass Zones
24
Using the Bypass Zones Function
24
Browser Feature
24
Zone Monitor
24
Testing Your System's Burglary Protection
24
Using the Zone Monitor Function
25
Browser Feature
25
System Status
25
Using the System Status Function
25
System Test
26
Using the System Test Function
26
Using the Panic Zone Test
26
User Proþ Les
27
Adding User Proþ Les
27
User Proþ Les Chart
28
Deleting User Proþ Les
29
Changing User Proþ Les
29
Temp Code
29
Alow: 1 2 3 4 any
29
Browser Feature
29
User Codes
30
Adding User Codes
30
Browser Feature
31
Deleting User Codes
31
Changing User Codes
31
Forgive Failure to Exit
32
Ambush Codes
32
Schedules
33
Setting Shift (S1 S2 S3 S4) Schedules
34
Setting Holiday ABC Schedules for S1, S2, S3, S4, out
36
And DOOR Schedules
36
Setting Holiday Dates (HOL)
37
Extending Schedules (EXT)
37
Setting the Date and Time
38
Setting the System's Date and Time
38
Display Events
38
Using the Display Events
39
Service Request
40
Fire Drill
40
Starting a Fire Drill Test
40
Ending a Fire Drill Test
40
System Setup
41
System Setup Record
41
Security Command Keypad Record
41
Which Keypads Display System Status
42
Which Keypads Display Armed Status
42
Which Keypads Provide Door Access Reports
42
Area Names and Numbers Record
43
User Proþ Les Record
44
User Codes Record
45
Schedules Record
46
Output Relay Record
47
Holiday Date Record
47
About the Display Events Section
48
Arming and Disarming Event Displays
48
Appendix A Zone Event Displays
48
User Code Change Event Displays
49
Supervisory Event Displays
49
System Monitor Event Displays
49
Door Access Event Displays
50
About Door Access
50
Schedule Change Event Displays
50
Zone Bypass Event Displays
51
Appendix B Zone Status Browser
52
Bypass Zones Browser
52
Zone Monitor Browser
53
Add User Codes Browser
53
Delete User Codes Browser
54
Change User Codes Browser
54
Entering User Names
55
XR500 User's Guide
55
Easy Entry™ User's Guide
56
Appendix C
56
Door Strike
56
Arming and Disarming an Area System
56
Disarming with Entry Delay
56
Using the Access Reader for User Menu Access
56
Frequently Asked Questions
57
Common Keypad Displays
58
Advertisement
Advertisement
Related Products
Security Command XT30
Security Command XT50
Security Command XRSuper6
Security Command XR500N
Security Command Executive XR200
Security Command XR100 Series
Security command XR40
Security Command XR200-485
Security Command Command Processor XR6
Security Command XR10 Executive Series
Security Command Categories
Security System
Keypad
Measuring Instruments
Control Panel
More Security Command Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL