Side View - Valor RetroFire RF24DN Installation And Owner's Manual

Direct vent fireplace insert
Table of Contents

Advertisement

Leveling the firebox in the hearth
The backside of each support leg has a leveling bolt. If necessary, adjust the level of the firebox in the hearth.
Leveling
bolt
Burner Module Reinstallation
Note: If the circulating fan is to be installed it should be done at this point before installing the burner
module. See instructions packaged with the fan for details of the fan installation.
Reinstall the burner module using the 10 screws removed previously. Note: The upper baffle may be removed to
gain more room for the screwdriver to install the rear screws.
Reinstall Burner
Module
(10 screws)
Gas Line Connection and Fire Unit Testing
Connect the gas line to the burner module. Check for leaks, purge the line, and test-fire the unit before installing the
window or proceeding with the remainder of the install—see section Lighting Instructions.
Top Baffle Reinstallation (if removed)
Edge Fits Into
Cleat at Back
Reinstall Top Baffle
(2 screws)
14
Firebox Installation
Leveling
bolt
Front View
Fret bracket
Leg
Front
Leveling bolt

Side View

Edge Fits Into
Cleat at Back
Remove Top Baffle
(2 screws)
Remove Top Baffle (optional)
(to provide space for a screwdriver)
Back