Vent Liner Rough-In; Appliance Preparation - Valor RetroFire RF24DN Installation And Owner's Manual

Direct vent fireplace insert
Table of Contents

Advertisement

Rough-in the two 3" diameter vent liners into existing chimney system being careful not to tear or damage the
liners in the process. It may be easier to install both liners at the same time rather than one at a time. Leave plenty
of liner at the bottom end if the Heater will be connected while on the hearth (see diagram). When connecting the
liner in this manner it is best to leave the top termination until later so the slack liner can be lifted after the insert
is in place (see separate section for top termination). Designate and mark the top and bottom of one liner as
"EXHAUST" to avoid confusion later.
Existing Fireplace
The size of the existing fireplace cavity will affect the method of installation. Smaller fireplaces, particularly factory-
built zero-clearance fireplaces will require the RF24 firebox to be disassembled then reassembled inside the
fireplace. Plan your particular installation accordingly.
Unpack appliance.
Remove window.
Remove log pack from firebox.
• Strip firebox down by removing:
• Burner Module (10 screws),
• Support Legs (2 screws per leg)
(required when inserting into
small fireplaces only)
Spring-loaded
Fastening Studs (2)
Remove Window
12

Vent Liner Rough-in

Appliance Preparation

1/4 Turn
Two 3" dia.
Aluminum Liners
Rough-In Liners
Remove
Burner
Module
(10 screws)
Remove
Support Legs
(2 screws/leg)