Allowable Vent Configurations
The RF24 is certified for use with approved 3" diameter
flexible venting installed into an approved existing solid
fuel burning masonry or factory built chimney system.
The venting system must terminate vertically at the
roof using an approved termination cap. Both inlet and
exhaust liners must be run continuously from appliance
to roof termination.
10"
10"
3" Inlet & Exhaust
Collars (exhaust collar
is slighthly longer)
559CLT
Termination

Vent Configurations

559CLT
Co-Linear Terminal
See
Chart
Where possible, avoid joints in flex pipe. If joints
are required, use only connectors approved by the
manufacturer of the flex pipe. Field fabricated joints are
not allowed.
Any generic 3" diameter flexible venting approved
for venting gas appliances is acceptable. See list of
the approved venting components on page 22 of this
manual.
40'
35'
30'
25'
20'
15'
10'
Allowable Horizontal Offset
Failure to position the parts in
accordance with these diagrams or
failure to use only parts specifically
approved with this appliance
may result in property damage or
personal injury.
3" Liners
3" min. Bend
Radius
WARNING
7