Specifications - Valor RetroFire RF24DN Installation And Owner's Manual

Direct vent fireplace insert
Table of Contents

Advertisement

Operating Your Fireplace for the First Time
When operating your new fireplace for the first time,
some vapors may be released due to the burning of
curing compounds used in the manufacture of the
appliance. They may cause a slight odor and could
cause the flames to be the full height of the firebox, or
even slightly higher, for the first few hours of operation.
This appliance is intended for installation into existing
masonry or factory-built, solid-fuel burning
fireplaces only.
Approvals and Codes
This appliance is certified to ANSI Z21.88-2009 /
CSA 2.33-2009 American National Standard / CSA
Standard for Vented Gas Fireplace Heaters for use in
Canada and the USA and to CGA 2.17-91 High Altitude
Standard in Canada. This appliance is for direct vent
installation terminating at the roof only.
Model RF24DVN is for use with Natural Gas only.
Model RF24DVP is for use with LPG only.
Conversion between fuels may only be done using the
approved conversion kits listed in the section Options.
This appliance complies with CSA P4.1-09 Testing
method for measuring annual fireplace efficiencies.
The installation must conform to local codes or, in the
absence of local codes with the National Fuel Gas
Code, ANSI Z223.1 or the Canadian Installation Code
CAN/CGA-B149. Only qualified licensed or trained
personnel should install this appliance.
This appliance, when installed , must be electrically
grounded in accordance with local codes, or in the
absence of local codes, with the National Electrical
Code, ANSI/NFPA 70 or the Canadian Electrical Code,
CSA C22.1.
Ratings
Model
Gas
Altitude (Ft.)*
Input Maximum (Btu/h)
Input Minimum (Btu/h)
Manifold Pressure (in w.c.)
Minimum Supply Pressure (in w.c.)
Maximum Supply Pressure (in w.c.)
Main Burner Injector Marking
Pilot Injector Marking
Safety and Warning Information

Specifications

NG
LPG
Natural
Propane
0-4,500 feet*
24,000
24,000
10,500
10,500
3.95
5.0
11.0
10.5
14.0
82-580
92-260
51
It is also possible that these vapors could set off any
smoke detection alarms in the immediate vicinity.
These vapors are quite normal on new appliances. We
recommend opening a window to vent the room. After
a few hours use, the vapors will have disappeared and
the flames will be at their normal height.
*High Altitude Installations
Input ratings are shown in BTU per hour and are
certified without deration for elevations up to 4,500 feet
(1,370 m) above sea level.
For elevations above 4,500 feet (1,370 m) in USA,
installations must be in accordance with the current
ANSI Z223.1 and/or local codes having jurisdiction.
In Canada, please consult provincial and/or local
authorities having jurisdiction for installations at
elevations above 4,500 feet (1,370 m).
9.5
30
5