INSTALLER

Check Operation

Turn the fi replace fl ame up and down using the
remote control to confi rm that the full range of inputs
is achieved—see the remote control operation
instructions on pages 8–11.

Adjust Aeration (if necessary)

Light the fi re and allow the unit to warm up for 10–15
minutes to evaluate the fl ame picture. Burners are
equipped with an adjustable shutter to control primary
aeration. See the fi gures below. The shutters are
factory-set to an aeration gap which will give optimum
performance for the vast majority of installations.
Air Shutters
Air Shutter
Slider & Cover
(natural gas)

Install Side Shrouds

The side shrouds are required to install the front on
the appliance. They are supplied with the engine.
Fit them to the appliance outer case as indicated
(2 screws/side).
See instructions supplied with the front trim for
installation of trim.
38
Installation
Natural gas
Close
Open
Close
Open
Depending of fuel bed used, altitude and other
considerations, the fl ame picture may be improved by
adjusting the aeration. The need for adjustment should
be determined only by operating the appliance with the
fuel bed, liners and window installed and evaluating the
fl ame picture after a 15-minute warm-up.
Increasing aeration (open) will cause the fl ames
to appear more transparent and blue showing more
ceramic eff ects glow.
Decreasing aeration (close) will cause the fl ames to
appear more yellow or orange showing less ceramic
eff ects glow.
Too little aeration may result in black carbon
forming and dropping into the fi rebox.