Program Example For Monitoring The Output Frequency - Mitsubishi Electric FR-A7NC Instruction Manual

Plug-in option
Hide thumbs Also See for FR-A7NC:
Table of Contents

Advertisement

8.4 Program example for monitoring the output frequency

The following explains a program to read monitor functions of the inverter.
The following program reads the output frequency of
Output frequency reading code number: H0001 (hexadecimal)
Refer to page 76 for the monitor code numbers.
(Example) The output frequency of 60Hz is indicated as H1770 (6000).
X0
X0F
X1
0
M0
X20
7
15
SW80.0
X100C
PROGRAMMING EXAMPLES
station 1
inverter to D1.
M0
Check the data link status of the station 1
Set monitor code (H01) of output frequency
MOV H1
W100
to RWw0.
Turn on the monitor command (RY0C)
Y100C
Read output frequency (RWr0) to D1
MOV W0
D1
when the monitoring (RX0C) turns on.
END
8
87

Advertisement

Table of Contents
loading

Table of Contents