EXAMPLE OF SAFETY SYSTEM
CONFIGURATION
FR-E800(-E) configuration example
RESET
Emergency
stop button
T1 X1 T0 X0 X3
NZ2GFSS2-32D
IO24V
IO24G
Programmable controller
CC-Link IE Field Network
remote I/O module (with safety functions)
NZ2GFSS2 - 32D/NZ2EXSS2 - 8TE

When the control logic is the sink logic, the common terminal is terminal SD.
NOTE
• When starting up the system operation, press the RESET switch to reset the safety stop function first.
• In the above configuration, after resetting the emergency stop button, the inverter will be in the safe-state until the RESET
switch is pressed.
CAUTION
 To prevent restart of the inverter when the power is restored after a power failure, 3-wire connection
is recommended for the START/STOP control. In case of 2-wire connection and using latching type
switch to short between STF and SD/PC for starting, ensure the compliance with safety standards for
the restarting when the inverter power is restored after a power failure.
8

EXAMPLE OF SAFETY SYSTEM CONFIGURATION

START
STOP
STOP
COM+ COM+
X2
Y2
Y1 Y0
COM-
NZ2EXSS2-8TE
IO24V
IO24G
Figure 3 Safety system example of the FR-E800(-E) inverter
FR-E800(-E)
SO
Logic
SOC
STF
S1
CPU
S2
SD
+24V
Fuse
PC
∗1
R/L1 S/L2 T/L3
Gate
Driver
IGBTs
CPU
Gate
Driver
U
M
W
V