Calculating Power Usage - Intel SRPL8 Product Manual

Intel server system product guide
Hide thumbs Also See for SRPL8:
Table of Contents

Advertisement

Table 37.
Minimum/Maximum Current Rating Configurations
Board
Minimum Configuration
I/O carrier
I/O carrier, I/O riser board
Profusion
Profusion carrier, processor mezzanine
carrier
board (one), Pentium III Xeon processor
(one), A450NX processor termination
modules (three)
Memory
Memory carrier, 128 MB DIMM (one) (one
carrier (each)
memory carrier only)
Front panel
Front panel
Midplane
Midplane
Peripheral
One diskette drive, one CD-ROM drive,
bay
SCSI backplane

Calculating Power Usage

Use the worksheet in Table 38 to calculate the total DC power used by your server configuration.
The documentation that comes with each add-in device should specify its current and voltage
requirements.
To calculate the total combined wattage for your server:
1. List the current for each board and device in the appropriate voltage level column in the table.
2. Add the currents in each column of the table.
3. Multiply the voltage by the total current to get the total wattage for each voltage level.
4. Add the total wattage for each voltage level to arrive at a total combined power usage on the
power supply.
194
Maximum Configuration
I/O carrier, I/O riser board, PCI adapter boards
(10 at maximum load)
Profusion carrier, processor mezzanine boards
(two), Pentium III Xeon processor
(eight at FMB maximum load), cache
coherency boards (two at 4 Tag configuration)
Memory carrier, 256 MB DIMM (16)
Front panel
Midplane
One diskette drive, one CD-ROM drive, two
hard disk drives, SCSI backplane