3.1.1.8
Scan module does not move to lock position
Cause
Flatbed CCD
board-main
control PCBA cable
failure.
Home position
sensor board
failure
Motor-main
control PCBA
connection failure
Motor failure
Power supply-main
control board
connection failure
Power supply fails.
N = See section 1.5.3 Wiring configuration
# = Refer to section 4.6
Relevant Unit
Check Method
Sensor board-main
Tester or visual
control PCBA cable
check
#
CCD board
Tester check
#
None
Visual check
Motor
Visual check
None
Visual check
Power supply
Tester check
(+24V, GND)
#
Table 3.2
3-9
Maintenance
Remark
Method
Replace the home
position cable.
Replace the CCD
None
PCBA
Connect the
None
connector.
Replace the
None
motor.
Connect the
None
connector.
Replace the power
None
supply.