UPS MAINTENANCE
44
Eaton 5115 Tower UPS (500–1400 VA) User's Guide
1400 VA models (see Figure 24:)
11. Disconnect the red battery cable.
12. Pull the battery out onto a flat, stable surface.
13. Disconnect the black battery cable to the UPS.
13
Figure 24. Removing the Battery (1400 VA Models)
14. Replace the battery. See "Recycling the Used Battery or UPS" on
page 45 for proper disposal.
15. Place the new batteries in the same position with the battery
terminals at the top.
16. Connect the black battery cable to the new battery.
17. Slide the batteries into the UPS. For 1400 VA models, be sure to
tuck the black cable connector between the middle and back
batteries to prevent damage.
18. Connect the red battery cable.
NOTE A small amount of arcing may occur when connecting the batteries. This is normal
and does not damage the unit or present any safety concern.
19. Replace the metal battery cover and UPS front cover.
12
S
05146640 Rev D www.eaton.com/powerquality