Adjusting the level of conductivity

Water contains, a variable quantity of limestone and
mineral salts of which quantities vary according to
geographical locations thus varying its conductivity
values.
Relevant variations of the conductivity of the water
compared to those prefixed by the factory could
slightly influence the residual humidity of the
laundry at the end of the cycle.
Your dryer allows you to regulate the sensitivity of
the drying sensor based on conductivity values of the
water by using the following procedure.
Procedure:
Turn the programme selector dial to switch on the
appliance.
In selection mode press the «Option» button until the
Set Up menu appears on the display.
Press «Change» button to enter in the Set Up menu
and then press the «Option» button sequentially until
the message «Water hardness» appears.
Adjusting the level of
conductivity:
Pressing «Change» button you can choose the
required water hardness degree.
The level of water hardness is indicated by 3 degree
shown on the display: hard, normal and soft.
07:07
Page 5
Display
Conductivity degree
S O F T
Low
N O R M A L
Medium
H A R D
High
Memorising the new
setting:
To fix your choice press the «Exit»button.
The previous selected drying cycle and options
appears again on the display and the buzzer sounds.
Normally, the appliance is factory-set to the
highest level; however, certain models may be
configured differently.
5
Approximative value
ºdH
< 14
15 - 21
> 21