INSTALLATION
Check the appliance is electrically safe and gas sound when you have finished.

Gas Connection

Fig.7-12
Must be in accordance with the relevant standards.
��
��
The gas supply needs to terminate with a down facing
bayonet.
���
Because the height of the cooker can be adjusted and
each connection is different it is difficult to give precise
���
dimensions. The hose should be fitted so that both inlet
and outlet connections are vertical so that the hose hangs
���
downwards in a 'U' shape (Fig.7-12).
The connector is located just below the hotplate level at the
rear of the cooker.
A flexible connection is supplied with the cooker. If it is
necessary to use another hose it must be to A.S. 1869 class B
and be suitable for your gas type.
If in doubt contact your supplier. Screw connect the threaded
end of the hose into the gas inlet.
After completing the gas connection, check the cooker is gas
sound with a pressure test.
ArtNo.062-0002 - 90SC - Prof+ - Gas connection

Pressure Testing

The pressure test point is accessible on the inlet pipe at the
rear. Remove the test nipple screw and fit a pressure gauge to
the test point. Turn on and light two of the hotplate burners.
For Natural Gas cookers the pressure should be 1kPa.
For Propane X cookers the pressure should be 2.54kPa.