Available languages

Levelling
You are recommended to use a spirit level on a shelf in one of the
ovens to check for level.
Place the cooker in its intended position taking care not to twist
it within the gap between the kitchen units as damage may occur
to the cooker or the units.
The rollers can be adjusted to level the cooker. To adjust the
height of the rear of the cooker use the levelling tool supplied to
turn the adjusting nuts at the front base of the cooker.
Adjust the height of the front roller to level the cooker. Turn
clockwise to raise the cooker and anticlockwise to lower.
When you are satisfi ed with the height and level raise the front
of the cooker by one turn of the front roller adjuster. Screw down
the front feet to meet the fl oor. Screw the front roller adjuster
anticlockwise to raise the front roller so that the front of the
cooker is supported on the feet, not the front roller, to prevent
accidental movement of the cooker.
Fitting the splash back (optional)
Remove the two fi xing screws (3mm hexagonal socket head) and
nuts that pass through the top of the rear fl ue grille. Hold the
splash back in position. From the rear refi t the 2 fi xing screws and
nuts.

Gas Connection

Restraining device
A restraining device should be fi tted when the cooker is
connected to a fl exible gas supply. Any restraining device should
be secured to the fabric of the building and should be able to be
released so that the cooker can be pulled out for cleaning and
maintenance.
Flexible Gas Hose
A gas shut off valve must be fi tted between the gas supply and
the connection hose. The fl exible hose (not supplied with the
cooker) must be in accordance with the relevant standards. If in
doubt contact, your supplier.
The gap between the cooker rear cover boxes and the rear wall
when the cooker is pushed back is only 50mm
The inlet connection on the cooker is ISO 7-1 internal. If you
require a ISO 228-1 connection fi nd the ISO 7-1 to ISO 228-1
connector in the conversion kit. Apply a suitable thread sealing
compound to the ISO 7-1 end.
Screw the connector into the cooker inlet until it is fi nger tight.
Using two suitable tools, one on the inlet on the cooker to make
sure it is held steady and one on the connector, tighten the
connector into the inlet on the cooker.Minimum torque 15Nm.
Maximum torque 20NmConnect the hose to the connector.
The hose should be fi tted so that both inlet and outlet
connections are vertical so that the hose hangs downwards in a
'U' shape. The gap between the cooker rear cover boxes and the
rear wall when the cooker is pushed back is only 50mm.
view from the rear
A appliance gas inlet
B position for gas supply connector, alternatively connect from the
side.
C electrical terminal cover
Because the height of the cooker can be adjusted and each
connection is diff erent it is diffi cult to give precise dimensions.
Ideally the house supply connection should be in the shaded
area shown in the fi gure showing the back of the cooker ('A' in the
fi gure). Alternatively connect from the side.
After completing the gas connection, check the cooker is gas
sound with a pressure test. When checking for gas leaks do
not use washing up liquid - this can corrode. Use a product
specifi cally manufactured for leak detection.
CAUTION: DO NOT USE A FLAME TO CHECK FOR GAS LEAKS.
Pressure testing
The gas pressure can be measured at the injector of one of the
centre hotplate burners. Remove the pan support, burner head
and cap. The injector is now accessible. Turn and light one of the
hotplate burners.
See Technical data section at the back of this book for test
pressures.
Reassemble burner top, making sure it is reassembled in the
correct way on the burner body.

Electrical Connection

This appliance must be installed by a qual i fi ed electrician to
comply with the relevant In sti tute of Electrical Engineers (I.E.E.)
regulations and also the local elec tric i ty supply company
re quire ments.
WARNING: THIS APPLIANCE MUST BE EARTHED
Note
The cooker must be connected to the cor rect electrical supply
as stated on the voltage la bel on the cooker, through a suitable
cooker control unit incorporating a double pole switch having a
contact separation of at least 3mm in all poles. This cooker must
not be connected to an ordinary domestic power point.
The total electrical load of this appliance is 11.7kW at 230VAC
It must be connected to an electrical supply, either single phase
or multi phase that can sustain a maximum current fl ow of at
least 51 amps. (Unless local regulations allow this loading to be
reduced by applying diversity factors).
51