Chapter 6: When There Is An Emergency; Emergency Alarm; Duress Alarm (Calling For Help); Telephone Alert To User - O.Y.L. Technology AX1 User Manual

Lcd & icon security & home automation system
Table of Contents

Advertisement

AX1 LCD & ICON User Manual

CHAPTER 6: WHEN THERE IS AN EMERGENCY

6.0

EMERGENCY ALARM

In order to access this function, the system must be in normal mode
COMMAND
If there is a „FIRE‟
Press [*] for 2 seconds
If there is a „EMERGENCY‟
Press [0] for 2 seconds
If there is a „PANIC‟
Press [#] for 2 seconds
6.1

DURESS ALARM (CALLING FOR HELP)

In the event where the user is forced by an intruder or robber to disarm the alarm system, user can
disarm the alarm system by using Duress Code. By pressing Duress Code, user can access the menu to
disarm the system. At the same time, a silent signal will be sent to any designated telephone number
or central monitoring station (CMS) to call for help. (* Provided the system is connected to CMS).
The siren and strobe will not be activated. To enter the duress menu, press [4 digit Duress Code] [#].
6.2

TELEPHONE ALERT TO USER

In case of any intrusion or emergency, this system will acknowledge users with an alarm report. The
panel will contact the user through fixed telephone or mobile line. If the user is unable to reply the
phone call, this system will call the user again. The default dialing attempts are 5 times. After 30
minutes, the system will call again. The number of repetition calls after 30 minutes depend on the
redial attempt set in the installer programming. The reporting comes in two reporting interface – no
voice or beeper interface reporting and voice interface reporting (if voice module is installed).
System will report the status of the system to user when an event happened accordingly to the list
below:
Reporting / Zone indication
Zone xx Violated
Zone xx Restored
Emergency
Fire
Panic
Help
AC Loss
AC Restore
Zone Bypass
Zone Bypass Restored
Tamper
System Armed
System Disarmed
Bell Loss
Bell Restored
DC Loss
DC Restored
System Reset
INFORMATION
 Alarm will be triggered
 A message will be sent to the Central Monitoring
Station (CMS)
 An alert tone or voice reporting will be sent
through telephone
Description
Zone has been violated
Alarm in zone xx has been restored
Emergency occurring
Fire occurring
Panic occurring
Duress Code has been entered
AC loss
AC restored
Zone has been bypassed
Zone has been restore from bypass
Tamper occurring
System has been armed
System has been disarmed
Bell loss
Bell restored
Battery loss/ low battery
Battery restored.
System has been re-power on.
Rev 4.0
32