© Elcom, s. r. o.
Figure 3.1 >
First system
flag values.
Figure 3.2 >
Second system
flag values.
Figure 3.3 >
Third system
flag values
20
System flags correction
1) To change the setting of any of the system
flags, switch the cash register into the "P"
mode by pressing
2) Enter the flag number to be edited and
press the
(RA) button.
3) Enter desired flag value and press the
(Subtotal) button.
4) Print the new programmed settings by
pressing the
(Check) button.
Flag 1 – Number of decimal places, method of rounding, TAX system...
Digit
Default
Meaning
setting
1
0
System of rounding:
2
0
Tax system:
3
2
No. of decimal places to which total price
should be rounded
4
2
No. of decimal places to which VAT should
by rounded
5
2
No. of decimal places to which price should
be rounded
6
2
No. of decimal places to which price, VAT
should be displayed
Flag 2 - TAX printing, number of logo lines, blank lines...
Digit
Default
Meaning
setting
1
1
TAX values printing
2
0
Date format
3
3
No. of decimal places of amount values
4
2
Number of blank lines between succeeding
receipts
5
6
Number of logo lines
6
0
Split pricing/successive multiplication entries
Flag 3 - Receipt consecutive number, cash register number
Digit
Default
Meaning
setting
1
0
Receipt consecutive number clearing
2 – 3
01
Cash register number
4 – 7
0001
Receipt consecutive number
Flag 4 - Required operations
Digit
Default
Meaning
setting
1
1
Subtotal amount printing after Subtotal key
is pressed
Euro-2100
5) Finish the programming by pressing the
Printing flags values
.
In the programming mode, select the flags
programming by pressing the
button. Press the
the flags values. It is possible to print the value
of currently programmed flag by pressing the
(EAN) button.
Programming manual
(Total) button.
(Check) button to print
Valid values
0 – up from 5, 1 – always up, 2 –
always down, 3 –special rounding
0 – VAT
1 – TAX
0 – 3
Valid values
0 – TAX values not printed,
1 – TAX values printed on receipt
0 – dd-mm-yy, 1 – mm-dd-yy
0 – 3
0 – 6)
0 – split pricing, 1 – successive
multiplication
Valid values
0 – after "Z" total (daily) report, 1
– after "Z" periodical report
(01 – 99)
(01 – 9 999)
Valid values
0 – no, 1 – yes
(RA)