Diagnostic Error Code
175-199-XXXThermal Sensor(s) test failed,
cause unknown
175-250-XXX
175-251-XXXThermal Sensor(s) limit error
185-000-XXXAsset Security Test Passed
185-XXX-XXXAsset Security failure
185-278-XXXAsset Security Chassis Intrusion
201-000-XXXSystem Memory Test Passed
201-XXX-XXXSystem Memory error
202-000-XXXSystem Cache Test Passed
202-XXX-XXXSystem Cache error
206-000-XXXDiskette Drive Test Passed
206-XXX-XXXDiskette Drive error
215-000-XXXCD-ROM Drive Test Passed
215-XXX-XXXCD-ROM Drive error
217-000-XXXHard Disk Drive Test Passed
FRU/Action
1. Go to the "Undetermined problems" section
2. Flash the system and re-test
3. Replace component under function test
1. Check fans
2. Check Power supply
3. Microprocessor
4. System board
1. No action
1. Flash system
2. System board
1. Assure Asset Security Enabled
2. C2 Cover Switch
3. System board
1. No action
1. Replace the memory module called out by the
test
2. System board
1. No action
1. Cache, if removable
2. System board
3. Microprocessor
1. No action
1. Diskette Drive Cable
2. Check power supply voltages
3. Diskette drive
4. System board
1. No action
1. CD-ROM Drive Cable
2. Check power supply voltages
3. CD-ROM drive
4. System board
1. No action
Chapter 1. IBM PC Enhanced Diagnostics error codes