Message/Symptom
Power-on indicator or hard disk drive in-use light
not on, but computer works correctly
Printer problems
Program loads from the hard disk with a
known-good diagnostics diskette in the first
3.5-inch diskette drive
Drives not recognized by the Fixed Disk diagnostic
(e.g., you have six drives but the fixed disk test
only shows three)
Hang during Fixed Disk diagnostic
RPL computer cannot access programs from its
own hard disk.
RPL computer does not RPL from server
Serial or parallel port device failure (system board
port)
Serial or parallel port device failure (adapter port)
FRU/Action
1. Power Supply
2. System Board
3. LED Cables
1. See "Printer" on page 107
1. Run Setup
2. Diskette Drive
3. Diskette Drive Cable
4. System Board
5. Power Supply
1. Remove the first drive that does not show up
and rerun the Fixed Disk diagnostic. If the
remaining drives then show up, replace the
drive you removed.
1. Remove the hard file being tested at the time
of the hang.
2. Rerun the diagnostic.
3. If successful, replace the drive you removed.
1. If network administrator is using LCCM
Hybrid RPL, check startup sequence:
a. First device - network
b. Second device - hard disk
2. Hard disk drive
1. Check startup sequence
2. Check the network adapter LED status
1. External Device Self-Test OK?
2. External Device
3. Cable
4. System Board
1. External Device Self-Test OK?
2. External Device
3. Cable
4. Alternate Adapter
5. System Board
Chapter 3. Types 6058/6059/6269/6578/6579
169