On-screen message
AmbientTempAlm02
P1 VCCP Alm XX
P1 VTT Alm XX
P1 VDDQ Alm XX
P1 DDR_VTT AlmXX
P2 VCCP Alm XX
P2 VTT Alm XX
P2 VDDQ Alm XX
P2 DDR_VTT AlmXX
BB +1.1v Alm XX
BB +1.5v Alm XX
BB +1.8v Alm XX
BB +3.3v Alm XX
BB +5v Alm XX
BB +0.9vs Alm XX
BB +1.1vs Alm XX
BB +1.8vs Alm XX
BB +3.3vs Alm XX
BB +5vs Alm XX
BB +12vs Alm XX
Battery Alm XX
Virtual LCD indications when STATUS lamp is flashing in amber
On-screen message
Mem Reconfigured
Mem Err Disable
CPU Reconfigured
E-Keying Error
Description
A low temperature error was
detected in CPU blade.
A voltage alarm was detected.
XX=09: Upper limit alarm
XX=02: Lower limit alarm
Description
The failing memory is forcedly
used, or the memory is degraded.
Correctable memory error
frequently occurs.
The failing CPU is forcedly used.
In the Blade Enclosure,
combination of installation
locations of CPU blade,
mezzanine card, and switch
module is not correct. Thus, an
unconformity of interface signal
was detected and the CPU blade
failed to power on.
General Description 2-11
Action
Check if the ambient temperature
of installation location satisfies the
operation guarantee condition.
If the same error persists, contact
your service representative.
Contact your service
representative.
Action
Check installation status of DIMM.
If the same error persists, contact your
service representative.
Check installation status of CPU.
If the same error persists, contact your
service representative.
Refer to the User's Guide of Blade
Enclosure for correct installation
locations.
If the same error persists, contact your
service representative.