NEC N8400-086F User Manual page 34

Express5800/bladeserver series
Table of Contents

Advertisement

2-10 General Description
Virtual LCD indications when STATUS lamp is flashing in red
On-screen message
Proc 1 IERR
Proc 2 IERR
WDT Timeout
WDT Power Down
SMI Timeout
ErrPause in POST
DUMP Request !
CPU1_DIMM U-Err
CPU2_DIMM U-Err
Proc Missing
Proc1 Config Err
Proc2 Config Err
MEZ1 Power Fault
MEZ2 Power Fault
IOH Thermal Trip
Proc1ThermalTrip
Proc2ThermalTrip
Proc1 Therm % 09
Proc2 Therm % 09
CPUx_DIMMyTemp09
AmbientTempAlm09
Description
An error was detected in CPU#1.
An error was detected in CPU#2.
Watchdog timer timeout error
occurred.
Forcedly powered off due to
watchdog timer timeout error.
A timeout error occurred while the
system management interrupt
process is in progress.
The system is waiting for key entry
due to serious POST error.
Under memory dump request
An uncorrectable memory error was
detected on CPU1_DIMM.
An uncorrectable memory error was
detected on CPU2_DIMM.
No CPU is installed in slot CPU#1.
The CPU installed in the CPU#1 slot
is unsupported or its combination is
illegal.
The CPU installed in the CPU#2 slot
is unsupported or its combination is
illegal.
An error was detected in power
circuit of mezzanine card installed in
Type 1 slot of CPU blade.
An error was detected in power
circuit of mezzanine card installed in
Type 2 slot of CPU blade.
Forced power-off occurred due to a
thermal error in chipset on CPU
blade.
Forced power-off occurred due to a
thermal error in CPU#1.
Forced power-off occurred due to a
thermal error in CPU#2.
A high temperature error was
detected in CPU #1.
A high temperature error was
detected in CPU #2.
A high temperature error was
detected in DIMM. x denotes CPU
number, and y denotes DIMM slot
number.
A high temperature error was
detected in CPU blade.
Action
Turn of the power once and then
on again.
If an error message appears on
POST screen, take note of the
message, and contact your service
representative.
If no error message appears,
check the IPMI information by
using the Off-line Maintenance
Utility.
Check the error message on
POST screen, take note of it, and
contact your service
representative.
Wait until dump collection
completes.
Check installation status DIMM.
If the same error persists, contact
your service representative.
Check installation status of CPU.
If the same error persists, contact
your service representative.
Check installation status of
mezzanine card.
If the same error persists, contact
your service representative.
Check installation status of the
heat sink on the CPU blade.
Check if fans in Blade Enclosure
work normally.
Refer to the User's Guide of the
Blade Enclosure to make sure that
the sufficient number of fans are
installed in correct locations.
Check if the fans and CPU blades
are installed in correct locations.
Check if the ambient temperature
of installation location satisfies the
operation guarantee condition.
If the same error persists, contact
your service representative.