52
Notes:
Related Commands:
css, roi
Example:
gla 10 20
Temperature Measurement
The temperature of the camera can be determined by using the
the internal chip temperature in degrees Celsius. For proper operation, this value should not exceed 75°C.
Note:
If the camera reaches 75°C, the camera will shut down and the LED will flash red. If this occurs,
the camera must be rebooted using the command,
to correct the temperature problem or the camera will shut down again.
Voltage Measurement
The command
displays the camera's input voltage. Note that the voltage measurement feature of the
vv
camera provides only approximate results (typically within 10%). The measurement should not be used
to set the applied voltage to the camera but only used as a test to isolate gross problems with the supply
voltage.
Camera Frequency Measurement
Purpose:
Returns the frequency for the requested Camera Link control signal
Syntax:
gsf m
Syntax Elements:
Example:
gsf
Returning Camera Settings
Returning All Camera Settings with the Camera Parameter
Screen
The camera parameter (
To read all current camera settings, use the command:
Syntax:
gcp
03-032-20135-00
≤
•
If x2
x1 then x2 is forced to be x1.
•
Analog gain, analog offset, digital offset, background subtract, and digital system
gain are applied to the data. FPN and PRNU coefficients are not included in the
data.
•
Values returned are in 12 bit DN.
•
Available in TDI Mode only.
Camera Link control signal to measure:
1: CC1 (EXSYNC)
3: Direction
) screen returns all of the camera's current settings.
gcp
command. This command will return
vt
or can be powered down manually. You will have
rc
Piranha HN RoHS User Manual
Teledyne DALSA