<WSW13> (Modem setting)
Selector No.
1
Cable equalizer
2
3
Reception level
4
5
I
Modem attenuator
8
• Selectors 1 and 2: Cable equalizer
These selectors are used to improve the pass-band characteristics of analogue signals on
a line. Attenuation in the high-band frequency is greater than in the low-band frequency.
Set these selectors according to the distance from the telephone switchboard to the
machine.
• Selectors 3 and 4: Reception level
These selectors set the optimum receive signal level.
• Selectors 5 through 8: Modem attenuator
These selectors are used to adjust the transmitting level attenuation of the modem when
the reception level at the remote station is improper due to line loss. This function applies
for G3 protocol signals.
Setting two or more selectors to "1" produces addition of attenuation assigned to each
selector.
If selector 8 on WSW23 is set to "0," this setting is so limited that 10 dB (1 dB in France) or
higher setting only is effective.
Note that in Japan and China, 9 dB or higher and 2 dB or higher settings only are effective,
respectively, regardless of whether selector 8 on WSW23 is set to "0."
Function
No. 1 2
No. 3 4
No. 5 6 7 8
App. 1-19
Setting and Specifications
0 0: 0 km
0 1: 1.8 km
1 0: 3.6 km
1 1: 5.6 km
0 0: -43 dBm
0 1: -47 dBm
1 0: -49 dBm
1 1: -51 dBm
0 0 0 0: 0 dB
0 0 0 1: 1 dB
0 0 1 0: 2 dB
0 0 1 1: 3 dB
0 1 0 0: 4 dB
1 1 1 1: 15 dB
Confidential

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents