Reinstallation Procedure
2. Reinstall the Original Glass.
3. Turn ON the Power Switch.
4. Carry out the adjustment procedure for CD-Mag. (see D-67). If the specifications are
not met, loosen the CCD Unit mounting screws and move the CCD Unit in the FD direc-
tion as necessary.
NOTE
• Hold the CCD Unit by hand when moving it. NEVER use a screwdriver or similar tool to
tap to move it, as a varied distance between the CCD sensor and lens results.
<Adjustment Procedure>
• If the specified width on the copy is less than the specifications, move the CCD Unit to
the left.
• If the specified width on the copy is longer than the specifications, move the CCD Unit to
the right.
Moving the CCD Unit over 1 mm results in the zoom ratio being varied about 2%.
5. Reversing the order of removal, reinstall all parts that have been removed.
1. Align the CCD Unit with the center of the gradua-
tions as illustrated on the left and then tighten the
four screws.
4025D116AA
D-9