Minolta CF2002 Service Manual page 274

Hide thumbs Also See for CF2002:
Table of Contents

Advertisement

Section
Step
Image
12 The problem is eliminated
Adjust
Back
ground Volt-
age Margin
(Tech. Rep.
Mode)
Gradation
13 "Conv. Value" falls within the
Adjust (Tech.
Rep. Mode)
Image Adjust
14 The problem has been elim-
PRT Max
Density (Tech.
Rep.Mode)
Image Adjust
15 The problem has been elim-
PRT High-
light (Tech.
Rep. Mode)
Image Adjust
16 After the Reset + Stabilizer
Stabilizer
Reset +
Stabilizer
(Tech. Rep.
Mode)
17 The problem has been elim-
Check Item
after Background Voltage
Margin has been adjusted.
specified range as checked
through Gradation Adjust.
Max: 0 ±100
Highlight = 0 ±60
inated through the adjust of
PRT Max.
inated through the adjust of
PRT Highlight.
sequence has been com-
pleted, run Gradation
Adjust; if the problem per-
sists, make adjustments of
PRT Max Density and PRT
Highlight.
inated through the checks of
steps up to 16.
T-96
Result
Action
NO
Go to next step.
NO
Go to step 17.
NO
Go to next step.
NO
Go to next step.
NO
Go to next step.
NO
Change IU.
Change LPH Assy.
Change PIC Board.
Change LED Drive Board.
Change LPH Unit.
Change High Voltage Unit
(Developing Bias).
Change High Voltage Unit
(Image Transfer, Neutralizing).

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cf3102

Table of Contents