Minolta CF2002 Service Manual page 161

Hide thumbs Also See for CF2002:
Table of Contents

Advertisement

Item
To fine-adjust the second trans-
fer output (ATVC) for the first
side and the second side,
2nd Transfer
respectively.
Adjust
When an image transfer fail-

ure occurs at the trailing edge
(of plain paper).
• Stabilizer
To run an image stabilization
sequence without clearing the
historical data of image stabili-
zation control.
When PRT Max Density, PRT

Highlight, or Background Volt-
age Margin has been
changed.
Stabilizer
• Reset + Stabilizer
To run an image stabilization
sequence by initializing the his-
torical data of image stabiliza-
tion control.
If gradation and max. density

are faulty even after a Stabi-
lizer has been run.
To adjust the set T/C level by
replenishing an auxiliary supply
of toner when a low ID occurs
due to a lowered T/C after large
numbers of copies have been
made of originals having a high
ATDC Toner
image density.
Supply
When there is a drop in T/C.

Turn this function ON when thin
paper (64 g/m2) is used in an
ambience of high temperature
Feeding
and high humidity in the 2-sided
double sided
mode.
THIN PAPER
It decreases the transfer output
value so as to prevent a paper
misfeed from occurring.
Purpose
S-28
Setting/Precautions
• Variable range: -5 to +5 (-500 V to
+500 V)
• Less foggy setting: Increase the set-
ting value.
• Foggier setting: Decrease the setting
value.
Pressing the Start key will let the copier
run an image stabilization sequence with
reference to the historical data. (This is
the same as that which is run when the
Power Switch is turned ON except that
no color shift adjustment is made.)
Pressing the Start key will let the copier
clear the historical data of the image sta-
bilization control and run an image stabi-
lization sequence based on the default
settings.
• Pressing the Start key will let the
copier detect the current toner density
and; if the density is lower than a ref-
erence value, a toner replenishing
sequence and then a developer agita-
tion sequence are run.
• These sequences are repeated up to
a maximum of four times until the
toner density reaches the reference
value. If the toner density is found to
be higher than the reference value,
only a developer agitation sequence is
carried out.
• The default setting is OFF.