CHAPTER 9
8354/8404
10. OUTSIDE HYDRAULIC EXTRACTION
10.1 HYDRAULIC BLOCK
A: To implement control valve "IN" port
B: From implement control valve "TANK" port
C: Without attaching implement
D: With attaching implement
NOTE:
•
When an implement is not attached, turn the slit on
the spool end to the horizontal position fully.
•
Remove the plugs from the OUT port (2) and IN port
(1) of the front hydraulic block (4).
•
Install the hydraulic take off adaptors (screw size
PT 3/8") to OUT port and IN port.
•
Connect the hydraulic hose to the adaptor (OUT port
side) and to the implement control valve IN port.
•
Connect the other hydraulic hose to the adaptor (IN
port side) an to the implement control valve TANK
(RETURN) port.
•
Turn the slit on the spool (3) end to the arrow side
fully as shown in the figure.
9-18
K&T Saw Shop 606-678-9623 or 606-561-4983
www.mymowerparts.com
(1) Inflow Port
(2) Outflow Port
(3) Spool
(4) Hydraulic Block Body
[A] To the Remote Valves
[B] From the Pump
615W920B
615W921A
D615-W03 May-2003