3.3 Main parts

8 sections
1. Control panel
The control panel gives priority to producing domestic hot water
2. Factory fitted bridge
Connection for gas pressure switch
Natural gas: 12.5 mbar
Propane: 20 mbar
3. a: Gas valve - Stage1 - Type VK4100C1026
b: Gas valve - Stage2 - Type VK4105C1066 (8-12 sections) -
Type VR4605CB1033 (14 sections)
4. a: Flame inspection window - Stage1
b: Flame inspection window - Stage2
5. Complete ignition burner
a: Ignition electrode: This ensures ignition burner ignition using
a high voltage spark.
b: Ionization probe: This detects the presence of a burner
ignition flame through ionization.
6. Safety box: The safety control box manages and checks the
boiler's ignition, operating and shutdown sequences.
Type Honeywell S 4565 BF 1161.
After resetting, the safety control box remains on standby for
around 1 minute.
7. Valve connector - Stage2
8. Safety control box and valve connector - Stage1
9. Downdraught thermostat: The downdraught thermostat
located in the draught diverter cuts off the gas supply and puts
the boiler into safety shutdown in the event of flue gas blow back
8 sections: Supplied
10-14 sections: Option (Factory fitted bridge) - Package RD19
10. Factory fitted bridge: Not used
04/01/11 - 300005180-001-C
10-14 sections
11. Factory fitted bridge
Connection for cyclical tightness controller (Option - Package
RD18)
GAS 360 S