3.3 Main parts

1
Control panel
2
Safety box
The safety control box is fitted to the control panel and controls the
burner ignition, function and extinction sequences.
3
Multivalve gas unit:
It includes a safety valve and a 2-stage principal valve with filter and
minimum gas pressure switch.
4
Ignition burner valve
5
Ignition burner
6
Flame inspection window
7
Ionization probe: It detects flame presence on the ignition burner by
flame ionization.
8
Ignition electrode: This ensures ignition burner ignition using a high
voltage spark.
9
Minimum gas pressure switch
(Minimum pressure: 12.5 mbar)
10 Ignition box
04/01/11 - 300005247-001-E