5
BASIC OPERATION

Lock function

This function electronically locks all keys (except for [PTT],
[DISTRESS] and [ ]) to prevent accidental channel changes
and function access.
Push [CLEAR/
ON and OFF.
• The lock function is automatically released when DSC call is
received, or [DISTRESS] is pushed.

Monitor function

The Monitor function opens the squelch by holding down
[VOL/SQL] for 1 second.
• "
" appears while the function is activated.
The function can be set to "PUSH" or "HOLD" in the following
manner.
q
Select "Configuration" in the "MENU" screen.
w
Select "Monitor" to enter the "Push" or "Hold" selecting mode.
• Push: The monitor function is activated by holding down [VOL/SQL]
for 1 second. The squelch opens while holding down the key.
• Hold: The monitor function is activated by holding down [VOL/
SQL] for 1 second. The squelch stays open until any key
is pushed.
15
] for 1 second to turn the lock function
Displayed when
the lock function
is activated.
AquaQuake water draining
function
The AquaQuake water draining function clears water away
from the speaker grill. Without this function, water may muffl e
the sound coming from the speaker. The transceiver emits a
vibrating beep when this function is activated.
While holding down [AQUA], the AquaQuake function is acti-
vated to clear water away from the speaker grill.
• Beep sounds, regardless of the volume level setting.
• Activates for 10 seconds in maximum to drain water.
• The transceiver never accepts key operation while the Aqua-
Quake function is activated.
• The AquaQuake function can not be activated when an optional
speaker-microphone is connected.

Backlight setting

This function lights the function display and keys, and it is
convenient for night-time operation.
q
Select
[BKLT] to enter the backlight adjusting mode.
w
Push
[∫]/[√] or [Ω]/[≈] to adjust the brightness level be-
tween 1(minimum) to 7 (maximum) or OFF.
• The default setting is 4.
• The display returns automatically to the main menu after 5 sec-
onds without no key operation is been performed.
• The backlight automatically turns OFF when no key operation
is performed for 5 seconds.