New2001
8
DSC OPERATION
D
Transmitting a Test call
Testing on the exclusive DSC distress and safety calling chan-
nels should be avoided as much as possible. When testing on
a distress/safety channel is unavoidable, you should indicate
that these are test transmissions.
Normally the test call would require no further communica-
tions between the two stations involved.
q
Enter "TEST CALL" in the DSC CALLS menu.
➪
❮MENU❯
(Push [MENU]) (Push [Y]/[Z], then push [ENTER].)
w
Select a desired preprogrammed individual address, or
"Manual Input," then push [ENTER].
• The ID code for the Individual call can be set fi
• When "Manual Input" is selected, set the 9 digit MMSI ID code for
the individual you wish to call.
41
➪
❮DSC Calls❯
❮Test Call❯
rst. (p. 20)
About Manual Inputting:
Enter a desired address ID in the following way:
• Select a desired number using [Ω]/[≈].
• Push [ENTER] to set it.
• To move the cursor, select either arrow, "←" or "→," then push
[ENTER].
• The fi rst digit is specifi ed as '0' for a Group ID. If a Group ID is
entered, an error beep sounds after pushing [FINISH].
• The fi rst two digits are '0' for any Coast station ID.
e
A confi rmation screen appears.
• Confi rm the call contents.