Table 12. INIT Command Generated Defaults (Continued)
Parameter
LED Operation
Low-Power Mode
Hold
RX Time-Out-Timer
RF Output Power
Transmitter
Test Frequency
Receiver
Test Frequency
Sleep Mode
Primary Extension
Radio Address
Synchronization
Source Map
Extended Address
For MASTER radios
AT Command
Support
Buffer Mode
Forward Error
Correction
Hop-Time
Low-Power Mode
Skipped Frequencies
Retry Count
Repeat Count

HREV

Hardware Revision

Shows the hardware revision of the radio.

KEY

Turn On Radio Transmitter Test Signal

Enables the transmitter. (Radio must be in Setup mode.) See also
command (DKEY
35
MDS TransNET Ref. Manual
Default Setting
OFF
0
None/Disable
30 dBm (1 watt)
915.000 MHz or
2436.0 MHz
(Model dependent)
915.000 MHz
2436.0 MHz
(Model-dependent)
OFF
0 (Master)
None
0
OFF
OFF
ON
7 ms
0 (Off)
None (radio will hop across all
frequencies)
10 (max. of 10 repeats for ARQ)
3 (downstream repeats)
Details, Page
33).
Corresponding
Command
LED
LPMHOLD
RXTOT
PWR 30
TX xxx
RX xxx
SLEEP OFF
XPRI 0
XMAP 0
XADDR 0
AT
BUFF OFF
FEC ON
HOPTIME 7
LPM
SKIP NONE
RETRY 10
REPEAT 3
DKEY