Hardware Revision
Initialize EEPROM
Defaults
Packaged Model
Initialization
MDS 05-3305A01, Rev. E
HREV
This command displays the transceiver's hardware revision level. If
nothing is displayed, the hardware revision level was not programmed
by the factory.
INIT
The
command is used to re-initialize the radio's operating parame-
INIT
ters to the factory defaults. This is helpful when trying to resolve con-
figuration problems that might have resulted from the entry of one or
more improper command settings. If you are unsure of which command
setting caused the problem, this command allows you to return to a
known working state. The following changes to the radio are made when
is entered:
INIT
•
is set to 0
CTS
•
is set to
DATAKEY
•
is set to
DEVICE
•
is set to 0
PTT
•
is set to 0
SCD
•
is set to 30 seconds and set to
TOT
•
is set to +37 dBm (5 watts)
PWR
All other commands stay in the previously established setting.
INIT [4710/9710]
This command sets the transceiver for "normal" operation outside the
P-20 chassis by setting the following parameters to the values shown
below:
ASENSE
ACTIVE HI
AMASK
FFFF FFFF
RXTOT
NONE
Use this command to restore these three parameters to the standard
transceiver defaults if it was used in a P20 package.
INIT [4720/9720]
This command sets the transceiver for service within a P-20 by setting
the following parameters to the values shown below:
ASENSE
ACTIVE LO
AMASK
FFFF 0000
(20 minute time-out timer)
RXTOT
20
MDS 4710/9710 Technical Manual
ON
DCE
ON
(assert alarm output on all alarms)
(receive time-out timer disabled)
(trigger on major alarms)
27