Command
DLINK [xxxxx/ON/OFF]
Page 32
DTYPE [NODE/ROOT]
Page 33
Table 9. Operational Configuration—Set/Program
Command
ADDR [1–65000]
29
AMASK [0000 0000–FFFF FFFF]
Details, Page 29
ASENSE [HI/LO]
29
BAND [A, B, C]
Details Page 30
BAUD [xxxxx abc]
Page 29
CODE [NONE, 1...255]
Page 31
CSADDR [1–65000, NONE]
Details, Page 31
CTS [0–255]
Details, Page 31
CTSHOLD [0–60000]
Page 32
DEVICE [DCE, CTS KEY]
Details, Page 32
MODE [M, R, X]
36
MRSSI [NONE, –40...–90]
Details, Page 37
OT [ON, OFF]
Details, Page 37
24
MDS TransNET Ref. Manual
Table 8. Network-Wide Diagnostics
Description
Controls operation of diagnostic link function.
Details,
Set radio's operational characteristics for
Details,
network-wide diagnostics
Description
Program network address
Details, Page
Alarm response
Default: FFFF FFFF
Sense of the alarm output on Pin 6 of the
Details, Page
DATA interface connector in the EIA-232
mode. Default: Alarm present = HI
Selects one of three operating bands.
(2.4 GHz Model Only)
Data communication parameters
Details,
Select the security/encryption setting in the
Details,
radio
Used on a single Master/Remote network to
support TDD-style simulated full-duplex.
CTS delay in milliseconds
(A value of 0 returns CTS immediately)
"Hold time" that CTS is present following last
Details,
character from DATA port.
Device behavior:
DCE (normal) or CTS Key
Operating mode:
Details, Page
M = Master, R = Remote, X = Extension
Minimum RSSI level required to preserve syn-
chronization with a Master radio for Remotes
in mobile service.
Enables a 1-second delay on delivery of RXD
serial data.
MDS 05-2708A01, Rev. F

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Transnet 2400Mds transnet 900Mds transnet 2400

Table of Contents