Performing Network-Wide Remote Diagnostics - GE TransNET 900 Reference Manual

Spread spectrum data transceiver
Hide thumbs Also See for TransNET 900:
Table of Contents

Advertisement

7.4 Performing Network-Wide Remote Diagnostics

Diagnostics data from a Remote radio can be obtained by connecting a laptop
or personal computer running MDS InSite diagnostics software (Version 6.6
or later) to any radio in the network.
NOTE: The diagnostics feature may not be available in all radios. The ability to query
and configure a radio via Network-wide Diagnostics is based on the feature op-
tions purchased in the radio being polled.
If a PC is connected to any radio in the network, intrusive polling (polling
which briefly interrupts payload data transmission) can be performed. To
perform diagnostics without interrupting payload data transmission, connect
the PC to a radio defined as the "root" radio. A radio is defined as a root radio
using the
DTYPE ROOT
A complete explanation of Remote diagnostics can be found in the
Network-Wide Diagnostics System Handbook (P/N 05-3467A01).
Table 20. Network-Wide Diagnostics Commands
Command
DLINK [xxxxx/ON/OFF]
Details, Page 32
DTYPE [NODE/ROOT]
Details, Page 33
1. Program one radio in the network as the root radio by entering the
DTYPE ROOT
2. At the root radio, use the
configure the diagnostic link protocol on the RJ-11 port.
3. Program all other radios in the network as nodes by entering the
DTYPE NODE
4. Use the
DLINK ON
diagnostic link protocol on the RJ-11 port of each node radio.
5. Connect a PC on which MDS InSite software is installed to the root radio,
or to one of the nodes, at the radio's diagnostics port.
To connect a PC to the radio's
03-3246A01) is required. If desired, an adapter cable may be constructed
from scratch, using the information shown in
6. Launch the MDS InSite application at the PC. (Refer to the InSite user's
manual for details.)
MDS 05-2708A01, Rev. F
command locally, at the radio.
Description
Set baud rate of diagnostics link
Set radio's operational characteristics for net-
work-wide diagnostics
command at the radio.
DLINK ON
command at each radio.
and
DLINK [baud rate]
DIAG
MDS TransNET Ref. Manual
and
DLINK [baud rate]
commands to configure the
port, an RJ-11 to DB-9 adapter (P/N
Figure 21 on Page
commands to
69.
49

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Transnet 2400Mds transnet 900Mds transnet 2400