GE TransNET 900 Reference Manual page 37

Spread spectrum data transceiver
Hide thumbs Also See for TransNET 900:
Table of Contents

Advertisement

Table 9. Operational Configuration—Set/Program (Continued)
Command
OWN [xxxxx]
Details, Page 37
PORT [RS232, RS485]
Page 37
PWR [20–30]
Details, Page 38
RXD [0–255]
Details, Page 39
RXTOT [NONE, 0–1440]
Details, Page 40
RTU [ON, OFF, 0-80]
Page 39
SLEEP [ON, OFF]
42
UNIT [10000–65000]
Page 43
XADDR [0–31]
Details, Page 44
XMAP [00000000-FFFFFFFF]
Details, Page 44
XPRI [0–31]
Details, Page 44
XRSSI [NONE, –40...–120]
Details, Page 44
ZONE CLEAR
Details, Page 44
Table 10. Operating Status—Display Only
Command
ADDR
Details Page 29
AMASK
Details Page 29
MDS 05-2708A01, Rev. F
Description
Owner's name, or alternate message
(30 characters maximum)
Data port (DATA connector) interface
Details,
signaling mode: RS232 or RS485
Power output in dBm
(Figure 30 on Page
Set RXD delay time for virtual seamless mode
with low latency
Maximum duration (in minutes) before
time-out alarm. Default is OFF.
Enable or Disable unit's built-in RTU
Details,
simulator. Default is OFF. Set RTU address
between zero and 80.
Enable or Disable the radio's energy-conser-
Details, Page
vation Sleep mode function.
Unit address used for network-wide
Details,
diagnostics. (Unique within associated net-
work.)
This unit's Extended address
Typically, the Master is set to zero (0).
Included Extended units in MODE X.
(Extensions and Remotes only)
Address of the primary Extended radio unit
(Extension).
Minimum RSSI level required to preserve syn-
chronization with a non-primary radio.
(Only meaningful when XPRI is not NONE)
Reset zone data statistics
Description
Network address
Alarm mask (response)
MDS TransNET Ref. Manual
76)
25

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Transnet 2400Mds transnet 900Mds transnet 2400

Table of Contents